A monolithic capillary electrophoresis system with integrated on-chip fluorescence detector has been microfabricated on a silicon substrate. Photodiodes in the silicon substrate measure fluorescence emitted from eluting molecules. The device incorporates an on-chip thin-film interference filter that prevents excitation light from inhibiting the fluorescence detection. A transparent AZO conducting ground plane is also used to prevent the high electric fields used for the separation from interfering with the photodiode response. Separations of DNA restriction fragments have been performed in these devices with femtogram detection limits using SYBR Green I intercalating dye.
منابع مشابه
Electrophoresis System with Integrated On-chip Fluorescence Detection
A monolithic capillary electrophoresis system with integrated on-chip fluorescence detection has been microfabricated on a silicon substrate. Photodiodes in the silicon substrate measure fluorescence emitted from eluting molecules. An on-chip thin film interference filter prevents excitation light from inhibiting the fluorescence detection. A transparent conducting ground plane prevents the hig...
متن کاملA simple light-emitted diode-induced fluorescence detector using optical fibers and a charged coupled device for direct and indirect capillary electrophoresis methods.
We constructed a simple fluorescence detector for both direct and indirect CE methods using a blue light-emitted diode (470 nm) as excitation source, a bifurcated optical fiber as a waveguide, and a CCD camera as a detector. The connection of all the components is fairly easy even for nonexperts and the use of a CCD camera improves the applicability of this detector compared to the others using...
متن کاملMicrofluidic genetic analysis with an integrated a-Si:H detector.
We have developed an integrated hydrogenated amorphous silicon (a-Si:H) fluorescence detector for microfluidic genetic analysis. It consists of a half-ball lens, a ZnS/YF3 multilayer optical interference filter with a pinhole, and an annular a-Si:H PIN photodiode allowing the laser excitation to pass up through the central aperture in the photodiode and the filter. Microfluidic separations of m...
متن کاملA collinear light-emitting diode-induced fluorescence detector for capillary electrophoresis.
A novel fluorescence detector based on collinear scheme using a brightness light-emitting diode emitting at 470nm as excitation source is described. The detector is assembled by all-solid-state optical-electronic components and coupled with capillary electrophoresis using on-column detection mode. Fluorescein isothiocyanate (FITC) and FITC-labeled amino acids and small molecule peptide as test ...
متن کاملMultiwavelength fluorescence detection for DNA sequencing using capillary electrophoresis.
Multiwavelength detection of laser induced fluorescence for dideoxynucleotide DNA sequencing with four different fluorophores and separation by capillary gel electrophoresis is described. A cryogenically cooled, low readout noise, 2-dimensional charge-coupled device is used as a detector for the on-line, on-column recording of emission spectra. The detection system has no moving parts and provi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 73 7 شماره
صفحات -
تاریخ انتشار 2001