A clinical comparison between two common transtibial Prosthetic suspension systems
نویسنده
چکیده
Introduction: Proper fitting of the stump inside the socket and appropriate selection of prosthetic suspension have positive effects on amputees’ satisfaction and could decrease gait deviation, skin problems, and stump atrophy. The suction sockets are commonly prescribed for transtibial amputees to have better suspension compared to the Pin and lock systems. The Seal-In® X5 (suction system) is a new suspension system that intend to decrease movement within the transtibial socket. The main intention of this study was to evaluate the effects of this liner on pistoning within the socket and patients satisfaction and to compare with a common pin and lock transtibial suspension system (Dermo liner). Methods: Ten unilateral transtibial amputees participated in this work and two prostheses (with suction socket and Pin/lock) were fabricated for each of them. The vertical displacement within the socket in static positions and during the gait (dynamic) was measured using Vicon motion system. The subjects were also asked to complete a prosthesis evaluation questionnaire (PEQ) for each suspension systems. Results: This study showed that the Seal-In could decrease pistoning movement inside the socket compare to the Pin and lock system. Moreover, during gait and static position a significant difference between the two suspension systems was found (p<0.05). However, this type of liner (seal-In) provided less pistoning during the ambulation but the overall satisfaction with the locking liner was higher (p<0.05) due to the relative ease with which the patients could don and doff the device. Discussion and Conclusion: Amputation rehabilitation is influenced by appropriate choice of prosthetic components in accordance with the real needs of the individual. We can infer from the results of this study that the Seal-In X5 liner decreased the pistoning within the prosthetic socket significantly, possibly as a result of the strong suction seal between the liner and the socket. Nevertheless, the subjects had difficulty with donning and doffing. We can therefore conclude that pistoning may not be the main factor that determines subjects’ overall satisfaction with the prosthesis. The study introduced a new method for evaluating the pistoning at the liner-socket interface in transtibial prostheses during gait. The Vicon system has the potential to detect the pistoning during gait while also offering a safer alternative to Xray. Further studies are needed to come to a “gold standard” for pistoning.
منابع مشابه
Transtibial prosthesis suspension systems: systematic review of literature.
BACKGROUND Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspensi...
متن کاملRe: "Quantitative and Qualitative Comparison of a New Prosthetic Suspension System with Two Existing Suspension Systems for Lower Limb Amputees".
OBJECTIVE The objectives of this study were to compare the effects of a newly designed magnetic suspension system with that of two existing suspension methods on pistoning inside the prosthetic socket and to compare satisfaction and perceived problems among transtibial amputees. DESIGN In this prospective study, three lower limb prostheses with three different suspension systems were fabricat...
متن کاملTranstibial prosthetic socket pistoning: static evaluation of Seal-In(®) X5 and Dermo(®) Liner using motion analysis system.
BACKGROUND The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and line...
متن کاملGait Biomechanics of Individuals with Transtibial Amputation: Effect of Suspension System
Prosthetic suspension system is an important component of lower limb prostheses. Suspension efficiency can be best evaluated during one of the vital activities of daily living, i.e. walking. A new magnetic prosthetic suspension system has been developed, but its effects on gait biomechanics have not been studied. This study aimed to explore the effect of suspension type on kinetic and kinematic...
متن کاملAn experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputees.
BACKGROUND Different suspension systems that are used within prosthetic devices may alter the distribution of pressure inside the prosthetic socket in lower limb amputees. This study aimed to compare the interface pressure of a new magnetic suspension system with the pin/lock and Seal-In suspension systems. METHODS Twelve unilateral transtibial amputees participated in the study. The subjects...