Reliability of the dynavision™ d2 for assessing reaction time performance.
نویسندگان
چکیده
Recently, the Dynavision™ D2 Visuomotor Training Device (D2) has emerged as a tool in the assessment of reaction time (RT); however, information regarding the reliability of the D2 have been limited, and to date, reliability data have been limited to non- generalizable samples. Therefore, the purpose of this study was to establish intraclass correlation coefficients (ICC2,1) for the D2 that are generalizable across a population of recreationally active young adults. Forty-two recreationally active men and women (age: 23.41 ± 4.84 years; height: 1.72 ± 0.11 m; mass: 76.62 ± 18.26 Kg) completed 6 trials for three RT tasks of increasing complexity. Each trial was separated by at least 48-hours. A repeated measures ANOVA was used to detect differences in performance across the six trials. Intraclass correlation coefficients (ICC2,1) standard error of measurement (SEM), and minimal differences (MD) were used to determine the reliability of the D2 from the two sessions with the least significant difference score. Moderate to strong reliability was demonstrated for visual RT (ICC2,1: 0.84, SEM: 0.033), and reactive ability in both Mode A and Mode B tasks (Mode A hits: ICC2,1: 0.75, SEM: 5.44; Mode B hits: ICC2,1: 0.73, SEM: 8.57). Motor RT (ICC2,1: 0.63, SEM: 0.035s) showed fair reliability, while average RT per hit for Modes A and B showed moderate reliability (ICC2,1: 0.68, SEM: 0.43 s and ICC2,1: 0.72, SEM: 0.03 s respectively). It appears that one familiarization trial is necessary for the choice reaction time (CRT) task while three familiarization trials are necessary for reactive RT tasks. In conclusion, results indicate that the Dynavision™ D2 is a reliable device to assess neuromuscular reactivity given that an adequate practice is provided. The data presented are generalizable to a population of recreationally active young adults. Key PointsThe Dynavision™ D2 is a light-training reaction device, developed to train sensory motor integration through the visual system, offering the ability to assess visual and motor reaction to both central and peripheral stimuli, with a capacity to integrate increasing levels of cognitive challenge.The Dynavision™ D2 is a reliable instrument for assessing reaction time in recreationally active young adults.It is recommended that one familiarization trial is necessary for the choice reaction time task assessment to learn the test protocol, while three familiarization trials are needed for reactive ability in Mode A and Mode B before a subsequent reliable baseline score can be established.Significant training effects were observed for all reaction time tests and should be taken into account with continuous trials.
منابع مشابه
Test-retest reliability of the Dynavision apparatus.
The Dynavision apparatus was developed to measure and train a number of psychomotor s u s , including visual scanning, peripheral visual awareness, and visuomotor reaction time (Performance Enterprises, 1992). Although several rehabilitation and human performance centers currently use the apparatus in occupational therapy and sport-related training, no reports of reliability have been published...
متن کاملTest-retest reliability of three Dynavision tasks.
The test-retest reliability of three Dynavision tasks of graded difficulty was estimated as high, with intraclass R correlation coefficients ranging from .88 to .97, and paired correlation coefficients ranging from .74 to .92. Recommendations are made for reliable testing procedures.
متن کاملSurvey of gender effect on driving performance and mental workload of Young Drivers using a driving simulator
Background and aims: Road traffic accident annually lead to the death of 1.2 million people and also the disability of some 50 million people in the world. Iran is one of the countries with the highest rates of road accidents in the world. According to the annual statistics by the Iranian Legal Medicine Organization, 15,932 people have lost their lives in road traffic accidents in 1395 sh. Acco...
متن کاملA Mathematical Approach for Describing Time-Dependent Poisson’s Ratios of Periodontal Ligaments
Periodontal ligament is a thin layer of soft tissue that connects root of a tooth to the surrounding alveolar bone. These ligaments play an important role in initiating tooth movement when loads are applied to teeth with orthodontic appliances. The majority of such soft tissues exhibit as viscoelastic bodies or have a time-dependent behavior. Due to the viscoelastic behavior of the periodontal ...
متن کاملThe Calotropis Gigantea Methanolic Extract Induces Apoptosis in Human Breast Carcinoma Cells
Background: Calotropis gigantea (family: Asclepiadaceae) has been known to contain cardiac glycosides. The C. gigantea extracts have been reported as cytotoxic to a few cancer cell lines. The present study was designed to examine the effect of Calotropis gigantea methanolic extract (CGME) on the growth and apoptosis in human breast carcinoma cell line (MCF-7 cells).Methods: The study was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 13 1 شماره
صفحات -
تاریخ انتشار 2014