Erratum to: Functionalized carbon nanotubes mixed matrix membranes of polymers of intrinsic microporosity for gas separation
نویسندگان
چکیده
Correction The authors regret to have overlooked an error in (Figure five) of the original version of this article [1]. The original, incorrect form (Figure 1), and the corrected form (Figure 2) are shown in this article. Figure 1 Synthesis of PIM-1, a-reagent and condition, K2CO3, DMAc and DEB at 150°C for 1 h (Incorrect form). Figure 2 Synthesis of PIM-1, a-reagent and condition, K2CO3, DMAc and DEB at 150°C for 1 h (Corrected form). which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
منابع مشابه
Functionalized carbon nanotubes mixed matrix membranes of polymers of intrinsic microporosity for gas separation
The present work reports on the gas transport behavior of mixed matrix membranes (MMM) which were prepared from multi-walled carbon nanotubes (MWCNTs) and dispersed within polymers of intrinsic microporosity (PIM-1) matrix. The MWCNTs were chemically functionalized with poly(ethylene glycol) (PEG) for a better dispersion in the polymer matrix. MMM-incorporating functionalized MWCNTs (f-MWCNTs) ...
متن کاملPurified and Functionalized MWCNTs: Application In CO2/CH4 Separation Using Mixed Matrix Membranes
To fabricate a defect free and high performance mixed matrix membrane (MMM), one approach is the functionalization of inorganic nanofillers (as dispersed phase) in the organic polymer matrix (as continuous phase) to modify the interactions between two phases. For this purpose,, raw multi-walled carbon nanotubes (rMWCNTs) were purified by acid mixture (HNO3/H2SO<sub...
متن کاملEffect of Ethylene Oxide Functional Groups in PEBA-CNT Membranes on CO2/CH4 Mixed Gas Separation
Poly (ether-block-amide) /poly (ethylene glycol)/ carbon nanotubes mixed matrix membranes have been successfully fabricated using solvent evaporation method to determine the effect of ethylene oxide groups on the performance of produced membranes. The effects of CNTs (2-8 wt%) and PEG (up to 50 wt%)were investigated in both single and mixed gas test setup in different temperature and pressure. ...
متن کاملComparative investigation on the correction factors of hydrogen permeability on CNTs-Mixed matrix membrane
This paper discusses different important gas permeation models such as “Maxwell”, “Bruggeman”, “Lewis-Neilson”, and “Pal” models to predict “Mixed Matrix Membranes” (MMMs) performance. The main parameter considered and discussed is the permeability of Hydrogen on Carbon Nanotubes (CNTs)-MMM. For evaluation of the theoretical models, experimental data of permeability for H2 were compa...
متن کاملComparative investigation on the correction factors of hydrogen permeability on CNTs-Mixed matrix membrane
This paper discusses different important gas permeation models such as “Maxwell”, “Bruggeman”, “Lewis-Neilson”, and “Pal” models to predict “Mixed Matrix Membranes” (MMMs) performance. The main parameter considered and discussed is the permeability of Hydrogen on Carbon Nanotubes (CNTs)-MMM. For evaluation of the theoretical models, experimental data of permeability for H2 were compa...
متن کامل