Interlamellar adhesive strength in human eyebank corneas.

نویسندگان

  • M K Smolek
  • B E McCarey
چکیده

The interlamellar biomechanical properties of stromal collagen are relatively unknown, yet may be highly significant with respect to wound healing and the efficacy of certain keratorefractive surgical procedures. Interlamellar adhesive strength was measured as the tearing force required to separate corneal lamellae at a 50% stromal depth in 16 human eyebank corneas. The mean value for the central cornea was found to be 14.2 (+/- 0.5 SEM) g-wt/mm of tissue width. Histology showed a smooth separation between the lamellae along the tearing plane in the central cornea. We believe that the adhesive strength measured in the central cornea may be primarily the force needed to break interlamellar proteoglycan bonds between collagen lamellae, because no torn lamellae were found in this region. The mean adhesive strength and the SEM increased toward the periphery in a symmetrical fashion. The mean adhesive strength in the far periphery was 31.6 (+/- 3.7 SEM) g-wt/mm at 5 mm nasally, and 28.4 (+/- 3.2 SEM) g-wt/mm at 5 mm temporally, and was approximately twice the mean central value. The rising value of the mean adhesive strength with increasing distance from the central cornea was believed to be due to a more highly disorganized collagen network in which greater numbers of lamellae passed obliquely in depth through the tearing plane. These lamellae would contribute their tensile strength to the adhesive strength measurement along the tearing plane. Histology from the peripheral cornea confirmed the existence of depth-varying collagen lamellae and the torn ends of lamellae that passed across the tearing plane.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interlamellar cohesive strength in the vertical meridian of human eye bank corneas.

PURPOSE Previously, human corneal stromal interlamellar cohesive strength in the horizontal meridian was shown to be twice as strong peripherally as centrally (approximately 2.90 x 10(-1) versus 1.40 x 10(-1) N/mm). In the current study, stromal samples excised from the vertical meridian were studied to determine if meridional differences also exist. Precise knowledge about corneal stromal stru...

متن کامل

Corneal hydration studied in stromal segments separated by interlamellar discs.

Interlamellar plastic discs inserted into cat corneas provide a means by which segments of the cornea can be studied with regard to swelling and water movement in vivo. The corneas are physiologically normal as demonstrated by their transparency, swelling properties, and histologic structure. The observation that one disc causes no change in the hydration of the stroma anterior or posterior to ...

متن کامل

Clinical evaluation and induced corneal vascularization study by native and anionic collagen membranes in rabbits corneas.

PURPOSE To evaluate the corneal vascularization (CV) and the clinical aspects induced by interlamellar graft with native (NCM) and anionic (ACM) collagen membranes in rabbits corneas. METHODS An interlamellar graft with a 0.25 x 0.25 cm NCM (group 1) or ACM (group 2) fragment was performed in the right eye (treated eye). In the left eye, an estromal tunnel was done (control eye). Sixteen rabb...

متن کامل

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems Dr. H. Kermanshah* - Dr. H. Haj miragha** - Dr. SH. Gatoeizadeh*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University / Medical Sciences. **- Assistant Professor of Fixed Prosthodontics Dept. & Dental Research Center - Faculty of Dentistry – Tehran Unive...

متن کامل

In vitro sealing of clear corneal cataract incisions with a novel biodendrimer adhesive.

OBJECTIVE To determine if a biodendrimer adhesive will seal a clear corneal cataract incision. DESIGN An experimental study in which 2.75-mm clear corneal cataract incisions were made in 8 human donor eyes. The corneas were mounted on an artificial anterior chamber. Leaking pressure was determined in 6 corneas. These corneas were then treated with adhesive and leaking pressure was again measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 1990