Analysis of Upper Limb Movement Range and Global Grip Strength After Surgical Treatment of AO Type C Distal Radius Fractures Using LCP Plates and K-wires.
نویسندگان
چکیده
BACKGROUND This paper presents the outcomes of treatment of AO Type C distal radius fractures using LCP plates and K-wires. The analysis focused on comparison of movement range and global grip strength between the operated limb and the healthy one. MATERIAL AND METHOD The study involved 60 patients treated in the Regional Specialist Hospital in Zgierz in the period 2008-2013. LCP plates were used in 31 cases and fixation with K-wires was employed in 29 patients. The movement range and grip strength were evaluated in line with the standards of orthopaedic examination, using a goniometer and a dynamometer. X-ray imaging was used to assess the bony anatomy. The results were subsequently compared with those for the healthy limb. RESULTS The analyses showed that neither approach produced a grip strength equal to that of the healthy limb. In two cases of Type C1 fractures treated using LCP plates, the movement range was the same as that of the other upper limb; these results were not obtained in any of the patients with K-wires. Superior outcomes were recorded for LCP plates; however, the differences were not significant. Radiographs revealed a significant difference in the degree of restoration of the articular surface, with LCP plates producing superior outcomes. CONCLUSIONS 1. The use of LCP plates enables more accurate restoration of the bone anatomy in the distal radius. 2. The mobility and grip strength of the limb were similar for both therapeutic procedures provided appropriate radiographic outcomes had been achieved. 3. The functional deficit in both groups was strongest for rotational movements of the forearm and grip strength of the limb.
منابع مشابه
Short-term Results of Using Injectable Bone Cement Technique in the Treatment of Unstable Distal Radius Fractures
Background & Aims: Treatment of osteoporotic distal radius fracture with metaphyseal defect is often complicated by secondary displacement, because of posterior cortex comminution. The aim of this study was to investigate functional outcomes and advantages of injection of bone cement in stabilizing and maintaining this fracture reduction. Methods: This prospective study was performed on 20 ...
متن کاملCharacteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures
OBJECTIVES To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type. METHODS A total of 136 patients who received either a 2.4 mm (n = 61) or 3.5 mm (n = 75) distal radius locking compression plate (LCP DR) using a volar approach were followed over two years. The main outcom...
متن کاملInterobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool
Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...
متن کاملScaphoid Fractures: A Comparison of Two Surgical Methods for Internal Fixation Using Either Herbert Screws or Multiple Pins
Background and Aims: Scaphoid fractures are the most common fractures of the wrist. This study compared the outcomes of two surgical internal fixation techniques, using either Herbert screws (HS group) or multiple pins (MP group), in the treatment of scaphoid fractures. Methods: This cross-sectional study was performed on 41 patients (23 in HS and 18 in MP groups) with unilateral scaphoid fract...
متن کاملDistal Radius Fracture Fixation With the Specialized Threaded Pin Device.
This study investigated the outcomes of extra-articular distal radius fractures and simple intra-articular radial styloid fractures stabilized with a novel threaded cannulated device. This was a retrospective study of 24 distal radius fractures treated with the T-Pin device (Union Surgical LLC, Philadelphia, Pennsylvania), with a minimum of 1 year of postoperative follow-up. Outcome data includ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ortopedia, traumatologia, rehabilitacja
دوره 18 3 شماره
صفحات -
تاریخ انتشار 2016