The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality.

نویسندگان

  • J H Maki
  • M R Prince
  • F J Londy
  • T L Chenevert
چکیده

The optimum infusion timing and k-space ordering for obtaining gadolinium-enhanced three-dimensional MR angiograms was determined through computer modeling using temporal contrast characteristics obtained from patient gadolinium infusion data. The effects of bolus timing were evaluated by varying the relationship between peak intravascular gadolinium concentration and the time at which the center of k space was acquired (tck) for sequential and centric acquisition techniques. Flow phantom experiments were performed to validate the theoretical computations. Gadolinium concentration at the time of central k-space acquisition determines intravascular signal intensity. Artifacts, including vessel broadening and edge ringing, depend on the order in which k space is collected and on how rapidly the gadolinium concentration changes. Artifacts are greatest when the center of k space is acquired before the intravascular gadolinium peak. Application of the optimal infusion timing results in preferential arterial enhancement with a minimum of artifacts in patients undergoing MR angiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of incomplete breath-holding on 3D MR image quality.

The purpose of this study was to investigate how fast three-dimensional (3D) MR image quality is affected by breath-holding and to develop an optimal breath-holding strategy that minimizes artifact in the event of an incomplete breath-hold. A computer model was developed to study variable-duration breath-holds during fast 3D imaging. Modeling was validated by 3D gradient-echo imaging performed ...

متن کامل

Myocardial perfusion and MR angiography of chest with SH U 555 C: results of placebo-controlled clinical phase i study.

PURPOSE To evaluate SH U 555 C for contrast material-enhanced three-dimensional magnetic resonance (MR) angiography of the chest and myocardial perfusion. MATERIALS AND METHODS For chest MR angiography, SH U 555 C was intravenously injected at four doses (5, 10, 20, and 40 micromol iron [Fe] per kilogram of body weight) into three healthy volunteers per dose group, and placebo (saline) was in...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Three-dimensional contrast-enhanced MR angiography of the extracranial carotid arteries: two techniques.

Two methods of contrast-enhanced dynamic 3-D MR angiography of the head and neck are demonstrated. In the first, arterial and arteriovenous phases are temporally resolved by timing contrast injection such that maximum arteriovenous signal intensity difference is matched to acquisition of central k-space. A second, faster sequence allows for temporal resolution of arterial, early arteriovenous, ...

متن کامل

Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography.

For time-resolved acquisitions with k-space undersampling, a simulation method was developed for selecting imaging parameters based on minimization of errors in signal intensity versus time and physiologic parameters derived from tracer kinetic analysis. Optimization was performed for time-resolved angiography with stochastic trajectories (TWIST) algorithm applied to contrast-enhanced MR renogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 1996