Transurethral resection of prostate: a comparison of standard monopolar versus bipolar saline resection.

نویسندگان

  • Piyush Singhania
  • Dave Nandini
  • Fernandes Sarita
  • Pathak Hemant
  • Iyer Hemalata
چکیده

INTRODUCTION Transurethral resection syndrome is an uncommon but potentially life threatening complication. Various irrigating solutions have been used, normal saline being the most physiological. The recent availability of bipolar cautery has permitted the use of normal saline irrigation. MATERIAL AND METHODS In a randomized prospective study, we compared the safety and efficacy of bipolar cautery (using 0.9% normal saline irrigation) versus conventional monopolar cautery (using 1.5% glycine irrigation). Pre and postoperative hemoglobin (Hb) and hematocrit values were compared. Hemodynamics and arterial oxygen saturation were monitored throughout the study. Safety end points were changes in serum electrolytes, osmolarity and Hb/PCV (packed cell volume). Efficacy parameters were the International Prostate Symptom Score (IPSS) and Qmax (maximum flow rate in mL/sec) values. RESULTS Mean preoperative prostate size on ultrasound was 60 +/- 20cc. Mean resected weight was 17.6 +/- 10.8 g (glycine) and 18.66 +/- 12.1 g (saline). Mean resection time was 56.76 +/- 14.51 min (glycine) and 55.1 +/- 13.3 min (saline). The monopolar glycine group showed a greater decline in serum sodium and osmolarity (4.12 meq/L and 5.14 mosmol/L) compared to the bipolar saline group (1.25 meq/L and 0.43 mosmol/L). However, this was not considered statistically significant. The monopolar glycine group showed a statistically significant decline in Hb and PCV (0.97 gm %, 2.83, p < 0.005) as compared to the bipolar saline group (0.55 gm % and 1.62, p < 0.05). Patient follow- up (1,3,6 and 12 months postoperatively) demonstrated an improvement in IPSS and Qmax in both the groups. CONCLUSION We concluded that bipolar transurethral resection of prostate is clinically comparable to monopolar transurethral resection of prostate with an improved safety profile. However, larger number of patients with longer follow up is essential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications and clinical outcome 18 months after bipolar and monopolar transurethral resection of the prostate.

PURPOSE To compare bipolar resection with the conventional monopolar transurethral resection of the prostate (TURP) with respect to peri- and postoperative complications and long-term outcome. PATIENTS AND METHODS Patients with consecutive benign prostatic hyperplasia needing surgery (n=185) from the hospital's waiting list were randomized to TURP using either a bipolar or a monopolar system....

متن کامل

Comparison of the haemostatic properties of conventional monopolar and bipolar transurethral resection of the prostate in patients on oral anticoagulants

INTRODUCTION The aim of study is comparing the haemostatic properties of conventional monopolar resection (TURP) and bipolar transurethral resection in saline (TURIS) of the prostate in patients under chronic oral anticoagulants. MATERIAL AND METHODS Out of a cohort group of 550 endoscopic resections for bladder outlet obstruction, 176 patients on chronic oral anticoagulant therapy required e...

متن کامل

A short-term evaluation of the safety and the efficacy of bipolar transurethral resection of the prostate in patients with a large prostate (>90 g)

OBJECTIVE To evaluate the efficacy and safety of bipolar transurethral resection of the prostate (TURP) in patients with a large prostate (>90 g), as a significant recent modification of TURP is the incorporation of bipolar technology, which uses the same technique as monopolar TURP but with normal saline as the irrigant. PATIENTS AND METHODS Forty patients with a prostate of >90 g and who we...

متن کامل

The Vista system: a new bipolar resection device for endourological procedures: comparison with conventional resectoscope.

OBJECTIVE Conventional transurethral resection of the prostate (TURP) uses a monopolar electrocautery system in which the current passes from the active electrode through the patient's body towards the return plate and may cause distant negative effects. In this study a new developed resection device, the Vista system, using a bipolar electrocautery system and 0.9% sodium chloride solution for ...

متن کامل

Bipolar energy in the treatment of benign prostatic hyperplasia: a current systematic review of the literature.

INTRODUCTION For decades, the monopolar transurethral resection of the prostate has been established as the minimally invasive surgical treatment for patients with benign prostatic hyperplasia (BPH). In recent years, new technologies and devices emerged to reduce the morbidity and improve outcomes for this treatment approach. Bipolar energy introduced the use of saline irrigation and laser tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International braz j urol : official journal of the Brazilian Society of Urology

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2010