The effect of reducing the number of electrodes on spatial hearing tasks for bilateral cochlear implant recipients.

نویسندگان

  • Ann Perreau
  • Richard S Tyler
  • Shelley A Witt
چکیده

BACKGROUND Many studies have documented the effect of reducing spectral information for speech perception in listeners with normal hearing and hearing impairment. While it is understood that more spectral bands are needed for unilateral cochlear implant listeners to perform well on more challenging listening tasks such as speech perception in noise, it is unclear how reducing the number of spectral bands or electrodes in cochlear implants influences the ability to localize sound or understand speech with spatially separate noise sources. PURPOSE The purpose of this study was to measure the effect of reducing the number of electrodes for patients with bilateral cochlear implants on spatial hearing tasks. RESEARCH DESIGN Performance on spatial hearing tasks was examined as the number of bilateral electrodes in the speech processor was deactivated equally across ears and the full frequency spectrum was reallocated to a reduced number of active electrodes. Program parameters (i.e., pulse width, stimulation rate) were held constant among the programs and set identically between the right and left cochlear implants so that only the number of electrodes varied. STUDY SAMPLE Nine subjects had used bilateral Nucleus or Advanced Bionics cochlear implants for at least 12 mo prior to beginning the study. Only those subjects with full insertion of the electrode arrays with all electrodes active in both ears were eligible to participate. DATA COLLECTION AND ANALYSIS Two test measures were utilized to evaluate the effect of reducing the number of electrodes, including a speech-perception-in-noise test with spatially separated sources and a sound source localization test. RESULTS Reducing the number of electrodes had different effects across individuals. Three patterns emerged: (1) no effect on localization (two of nine subjects), (2) at least two to four bilateral electrodes were required for maximal performance (five of nine subjects), and (3) performance gradually decreased across conditions as electrode number was reduced (two of nine subjects). For the test of speech perception in spatially separated noise, performance was affected as the number of electrodes was reduced for all subjects. Two categories of performance were found: (1) at least three or four bilateral electrodes were needed for maximum performance (five of seven subjects) and (2) as the number of electrodes were reduced, performance gradually decreased across conditions (two of seven subjects). CONCLUSION Large individual differences exist in determining maximum performance using bilateral electrodes for localization and speech perception in noise. For some bilateral cochlear implant users, as few as three to four electrodes can be used to obtain maximal performance on localization and speech-in-noise tests. However, other listeners show a gradual decrement in performance on both tasks when the number of electrodes is reduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Recognition and localization of speech by adult cochlear implant recipients wearing a digital hearing aid in the nonimplanted ear (bimodal hearing).

BACKGROUND The use of bilateral amplification is now common clinical practice for hearing aid users but not for cochlear implant recipients. In the past, most cochlear implant recipients were implanted in one ear and wore only a monaural cochlear implant processor. There has been recent interest in benefits arising from bilateral stimulation that may be present for cochlear implant recipients. ...

متن کامل

Evaluation of Saccular Function Pre-Post Cochlear Implant Surgery Using VEMPs

Objectives: The aim of present study was evaluation of saccule function in cochlear implant candidates with severe to profound sensory neural hearing loss Before and after cochlear implantation Methods: In this study 35 cochlear implant (CI) candidates with bilateral severe to profound sensory neural hearing loss before and about 30 days after cochlear implant and 20 normal-hearing cases as ...

متن کامل

COCHLEAR IMPLANTATION IN IRAN

Cochlear implantation has become an increasingly common procedure in the rehabilitation of selected cases of profound deafness.' Patients should have profound total bilateral sensorineural hearing loss. Sound is transformed into small electric currents which stimulate the auditory nerves in the cochlea and generate the hearing sensation. The nucleus cochlear implant is the result of more t...

متن کامل

EFFECT OF A UDITORY-VERBAL REHABILITATION ON VOICE PARAMETERS IN CHILD COCHLEAR IMPLANT USERS

This study aimed to evaluate the effects of auditory-verbal rehabilitation on voice parameters after implantation with cochlear implants 2 and 5 months after rehabilitation and compare them with normal voice children (under 12 years of age). A perceptive and electroacoustic evaluation of voice was carried out through a digital analysis after implantation and rehabilitation. The study was pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2010