Evaluation of Dimensional and Flow Properties of ExPress Glaucoma Drainage Devices.
نویسندگان
چکیده
PURPOSE ExPress devices are available as P50 and P200 models, the numbers related to their luminal diameters in μm. We compared their Poiseuille's Law-based theoretical resistance values with experimental values and correlated these with their luminal dimensions derived from electron microscopy. METHODS Scanning electron microscopy was performed on P50 and P200 devices. Bench-top flow studies were performed to find the resistances of the devices. Devices were also incorporated into a perfused, ex vivo porcine sclera model to test and compare their control of pressure, with and without overlying scleral flaps, and with trabeculectomies. RESULTS The luminal dimensions of the P200 device were 206.4±3.3 and 204.5±0.9 μm at the subconjunctival space and anterior chamber ends, respectively. Those of the P50 device were 205.0±5.8 and 206.9±3.7 μm, respectively. There were no significant differences between the P200 and P50 devices (all P>0.05). The resistances of the P200 and P50 devices were 0.010±0.001 and 0.054±0.002 mm Hg/μL/min, respectively (P<0.05). Equilibrium pressures with overlying scleral flaps were 17.81±3.30 mm Hg for the P50, 17.31±4.24 mm Hg for the P200, and 16.28±6.67 mm Hg for trabeculectomies (P=0.850). CONCLUSIONS The luminal diameters of both devices are externally similar. The effective luminal diameter of the P50 is much larger than 50 μm. Both devices have low resistance values, making them unlikely to prevent hypotony on their own. They lead to similar equilibrium pressures as the trabeculectomy procedure when inserted under the scleral flap.
منابع مشابه
Resonant magnetoelastic microstructures for wireless actuation of liquid flow on 3D surfaces and use in glaucoma drainage implants
Magnetoelastic resonators made from metal alloy foils are widely used for miniature wireless anti-theft tags and have also been explored for use in various sensing applications. Through annealing within three-dimensional (3D) molds, these foils can be formed into curved structures. Consequently, magnetoelastic materials present an opportunity for the development of a new class of wireless, actu...
متن کاملArtificial drainage devices for glaucoma surgery: an overview.
Artificial drainage devices (ADD) create an alternative pathway for aqueous drainage from the anterior chamber of an eye through a tube to the subconjunctival bleb connected to an equatorial plate under the conjunctiva. The ADDs, both valved and non-valved, are available for end stage or refractory glaucoma. Currently, some of these devices, particularly the Express shunt, are recommended for t...
متن کاملImpact of the Confluence Angle on Flow Field and Flowmeter Accuracy in Open Channel Junctions
Open channel junction is one of the most common hydraulic structures that are used in various practical situations such as sewer, drainage, and flood control systems. Knowing the fluid flow behavior, is one of the most important topics in designing the efficient open channel junctions. The complexity and deviation of flow in the junction’s zone disrupts the proper functioning of the flowmeter d...
متن کاملEvaluation of Hydraulic Sensitivity Indicators for Baffle Modules (Case Study: Varamin Irrigation and Drainage Network)
Measuring sensitivity of hydraulic structures is considered as an approach for evaluation of water projects performance, due to lower distribution efficiency in Irrigation and Drainage project schemes. Sensitivity analysis approach for irrigation structures is one of flow analysis methods which are developed in recent years in order to measure the behavior of flow in hydraulic structures in an ...
متن کاملDevelopment of a Test Facility for Microfluidic Characterization of Glaucoma Drainage Devices.
Microfluidic characterization plays an outstanding role in the development of glaucoma drainage devices. Here, we describe the optimization of an existing test facility with regard to measurement of small volumetric flow rates in the range of 1 μl/min to 40 μl/min in a minimized testing time. The existing test facility is extended by a flow sensor and validated by microfluidic characterization ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of glaucoma
دوره 25 1 شماره
صفحات -
تاریخ انتشار 2016