چکیده

Despite several decades of research, electrically powered hand and arm prostheses are still controlled with very simple algorithms that process the surface electromyogram (EMG) of remnant muscles to achieve control of one prosthetic function at a time. More advanced machine learning methods have shown promising results under laboratory conditions. However, limited robustness has largely prevented the transfer of these laboratory advances to clinical applications. In this paper, we introduce a novel percutaneous EMG electrode to be implanted chronically with the aim of improving the reliability of EMG detection in myoelectric control. The proposed electrode requires a minimally invasive procedure for its implantation, similar to a cosmetic micro-dermal implant. Moreover, being percutaneous, it does not require power and data telemetry modules. Four of these electrodes were chronically implanted in the forearm of an able-bodied human volunteer for testing their characteristics. The implants showed significantly lower impedance and greater robustness against mechanical interference than traditional surface EMG electrodes used for myoelectric control. Moreover, the EMG signals detected by the proposed systems allowed more stable control performance across sessions in different days than that achieved with classic EMG electrodes. In conclusion, the proposed implants may be a promising interface for clinically available prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time robustness evaluation of regression based myoelectric control against arm position change and donning/doffing

There are some practical factors, such as arm position change and donning/doffing, which prevent robust myoelectric control. The objective of this study is to precisely characterize the impacts of the two representative factors on myoelectric controllability in practical control situations, thereby providing useful references that can be potentially used to find better solutions for clinically ...

متن کامل

A Novel Research and Clinical Approach to Using Gel Liners for Collection of Surface Myoelectric Signals for Prosthetic Control

For more than two decades, individuals with lower limb amputations have been successfully fitted with gel liners constructed from a variety of materials. Prosthetists have also reported moderate success with gel liners fit to individuals with upper limb amputations who use externally powered prostheses. At the Center for Bionic Medicine, we have explored a novel approach to collecting myoelectr...

متن کامل

Towards Robustness in Pattern Recognition Based Myoelectric Prosthesis Control

Commercial myoelectric prosthetic systems are based on relatively simple signal acquisition and processing. Academic research has indeed been developing powerful algorithms with promising results (e.g., pattern recognition methods and linear or non-linear transformations [1-4]), but there are still no commercial systems available using these approaches because they are not robust enough for cli...

متن کامل

Echo State Networks as Novel Approach for Low-Cost Myoelectric Control

Myoelectric signals (EMG) provide an intuitive and rapid interface for controlling technical devices, in particular bionic arm prostheses. However, inferring the intended movement from a surface EMG recording is a non-trivial pattern recognition task, especially if the data stems from lowcost sensors. At the same time, overly complex models are prohibited by strict speed, data parsimony and rob...

متن کامل

Toward Optimizing Electrode Configurations to Improve Myoelectric Pattern Recognition

Standard myoelectric control systems use carefully placed bipolar electrode pairs to provide independent myoelectric signals (MESs) for prosthesis control. Because myoelectric pattern recognition systems do not require isolated MESs, the two electrode poles used for each MES channel may be placed longitudinally along individual muscles or transversely across multiple muscles. In addition, each ...