Quirks of Error Estimation in Cross-Linking/Mass Spectrometry

نویسندگان

  • Lutz Fischer
  • Juri Rappsilber
چکیده

Cross-linking/mass spectrometry is an increasingly popular approach to obtain structural information on proteins and their complexes in solution. However, methods for error assessment are under current development. We note that false-discovery rates can be estimated at different points during data analysis, and are most relevant for residue or protein pairs. Missing this point led in our example analysis to an actual 8.4% error when 5% error was targeted. In addition, prefiltering of peptide-spectrum matches and of identified peptide pairs substantially improved results. In our example, this prefiltering increased the number of residue pairs (5% FDR) by 33% (n = 108 to n = 144). This number improvement did not come at the expense of reduced accuracy as the added data agreed with an available crystal structure. We provide an open-source tool, xiFDR ( https://github.com/rappsilberlab/xiFDR ), that implements our observations for routine application. Data are available via ProteomeXchange with identifier PXD004749.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemical cross-linking and mass spectrometry to map three-dimensional protein structures and protein-protein interactions.

Closely related to studying the function of a protein is the analysis of its three-dimensional structure and the identification of interaction sites with its binding partners. An alternative approach to the high-resolution methods for three-dimensional protein structure analysis, such as X-ray crystallography and NMR spectroscopy, consists of covalently connecting two functional groups of the p...

متن کامل

Mass spectrometry evidence for cisplatin as a protein cross-linking reagent.

Cisplatin is a potent anticancer drug, which functions by cross-linking adjacent DNA guanine residues. However within 1 day of injection, 65-98% of the platinum in the blood plasma is protein-bound. It is generally accepted that cisplatin binds to methionine and histidine residues, but what is often underappreciated is that platinum from cisplatin has a 2+ charge and can form up to four bonds. ...

متن کامل

Probing Native Protein Structures by Chemical Cross-linking, Mass Spectrometry, and Bioinformatics*

Chemical cross-linking of reactive groups in native proteins and protein complexes in combination with the identification of cross-linked sites by mass spectrometry has been in use for more than a decade. Recent advances in instrumentation, cross-linking protocols, and analysis software have led to a renewed interest in this technique, which promises to provide important information about nativ...

متن کامل

Cross-Linking Electrochemical Mass Spectrometry for Probing Protein Three-Dimensional Structures

Chemical cross-linking combined with mass spectrometry (MS) is powerful to provide protein three-dimensional structure information but difficulties in identifying cross-linked peptides and elucidating their structures limit its usefulness. To tackle these challenges, this study presents a novel cross-linking MS in conjunction with electrochemistry using disulfide-bond-containing dithiobis[succi...

متن کامل

Does chemical cross-linking with NHS esters reflect the chemical equilibrium of protein-protein noncovalent interactions in solution?

Chemical cross-linking in combination with mass spectrometry has emerged as a powerful tool to study noncovalent protein complexes. Nevertheless, there are still many questions to answer. Does the amount of detected cross-linked complex correlate with the amount of protein complex in solution? In which concentration and affinity range is specific cross-linking possible? To answer these question...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 89  شماره 

صفحات  -

تاریخ انتشار 2017