Detection and localization of multiple epicardial electrical generators by a two-dipole ranging technique.

نویسندگان

  • D M Mirvis
  • F W Keller
  • R E Ideker
  • J W Cox
  • R F Dowdie
  • D G Zettergren
چکیده

The ability of a numerical procedure to detect and to localize two experimentally induced, epicardial dipolar generators was tested in 24 isolated, perfused rabbit heart preparations, suspended in an electrolyte-filled spherical tank. Electrocardiograms were recorded from 32 electrodes on the surface of the test chamber before and after placement of each of two epicardial burns. The second lesion was located either 180 degrees, 90 degrees, or 45 degrees from the first. Signals were processed by iterative routines that computed the location of one or two independent dipoles that best reconstruced the observed surface potentials. The computed single dipole acounting for 99.68% of root mean sequare (RMS) surface potential recorded after the first burn was located 0.26 +/- 0.10 cm from the centroid of the lesion. Potentials recorded after the second lesions were fit with two dipoles that accounted for 99.36 +/- 1.51% of RMS surface potentials and that were located 0.42 +/- 0.26 cm and 0.57 +/- 0.49 cm from the centers of the corresponding burn. Seventy-one percent of computed dipoles were located within the visible perimeter of the burn. Thus, two simultaneously active dipolar sources can be detected and accurately localized by rigorous study of the generated electrical field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...

متن کامل

Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique

Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulat...

متن کامل

A Simple Analytic Method to Model and Detect Non-Uniform Air-Gaps in Synchronous Generators

The air-gap of electrical machines may become non-uniform due to low accuracy of the manufacturing machinery, in assembling processes, or by aging. Detection and monitoring of this phenomenon is very important and of interest. There are several methods to model non-uniform air-gaps and to detect them by monitoring systems. One of the most widely used methods is by the analysis of the line curre...

متن کامل

Design, Simulation and implementation of active dual-band dipole antenna using a series stub

In this paper, a new method for designing an active dual-band dipole antenna is proposed. The operating frequencies of the proposed antenna are 150 and 450 MHz that are usually used in military applications. Using a series stub is the main idea in the proposed dual-band antenna, where it makes an independent resonance frequency higher than the main resonance frequency of a conventional dipole. ...

متن کامل

Internal Fault Detection, Location, and Classification in Stator Winding of the Synchronous Generators Based on the Terminal Voltage Waveform

In this paper, a novel method is presented for detection and classification of the faultyphase/region in the stator winding of synchronous generators on the basis of the resulting harmoniccomponents that appear in the terminal voltage waveforms. Analytical results obtained through DecisionTree (DT) show that the internal faults are not only detectable but also they can be classified andthe rela...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 1977