Measuring Cytotoxicity by Bioluminescence Imaging Outperforms the Standard Chromium-51 Release Assay

نویسندگان

  • Mobin A. Karimi
  • Eric Lee
  • Michael H. Bachmann
  • Ana Maria Salicioni
  • Edward M. Behrens
  • Taku Kambayashi
  • Cynthia L. Baldwin
چکیده

The chromium-release assay developed in 1968 is still the most commonly used method to measure cytotoxicity by T cells and by natural killer cells. Target cells are loaded in vitro with radioactive chromium and lysis is determined by measuring chromium in the supernatant released by dying cells. Since then, alternative methods have been developed using different markers of target cell viability that do not involve radioactivity. Here, we compared and contrasted a bioluminescence (BLI)-based cytotoxicity assay to the standard radioactive chromium-release assay using an identical set of effector cells and tumor target cells. For this, we stably transduced several human and murine tumor cell lines to express luciferase. When co-cultured with cytotoxic effector cells, highly reproducible decreases in BLI were seen in an effector to target cell dose-dependent manner. When compared to results obtained from the chromium release assay, the performance of the BLI-based assay was superior, because of its robustness, increased signal-to-noise ratio, and faster kinetics. The reduced/delayed detection of cytotoxicity by the chromium release method was attributable to the association of chromium with structural components of the cell, which are released quickly by detergent solubilization but not by hypotonic lysis. We conclude that the (BLI)-based measurement of cytotoxicity offers a superior non-radioactive alternative to the chromium-release assay that is more robust and quicker to perform.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring human mast cell-mediated cytotoxicity against human tumour cells: three-colour flow cytometry using monoclonal antibody target staining with annexin V / propidium iodide co-labelling of death.

BACKGROUND Chromium release assay is the standard method for evaluation of cell-mediated cytotoxicity, including that of mast cells. Although this is a reproducible method, it has more drawbacks than even radioactivity. In addition to the shortcoming of measuring only necrotic killing, some non-radioactive methods have not been widely used either. The numerous limitations of these methods led r...

متن کامل

A new neutrophil candida killing test: chromium-51 release from Candida guilliermondii.

Neutrophil candidacidal function was measured by a chromium-51 (51Cr) release technique, using Candida guilliermondii as the test organism. The effect of varying the neutrophil:candida ratio, the time course of 51Cr release, the effect of different serum concentrations, and the reproducibility of the technique were investigated. Results from 33 experiments, using neutrophils from 35 normal dono...

متن کامل

A Novel Method for Assessment of Natural Killer Cell Cytotoxicity Using Image Cytometry

Natural killer (NK) cells belong to the innate arm of the immune system and though activated NK cells can modulate immune responses through the secretion of cytokines, their primary effector function is through target cell lysis. Accordingly, cytotoxicity assays are central to studying NK cell function. The 51Chromium release assay, is the "gold standard" for cytotoxicity assay, however, due to...

متن کامل

A Simple and Sensitive Method for Measuring Tumor-Specific T Cell Cytotoxicity

A simple and sensitive method to quantitatively measure the cytolytic effect of tumor-specific T killer cells is highly desirable for basic and clinical studies. Chromium (51Cr) release assay has been the "gold standard" for quantifying cytolytic activities of cytotoxic T lymphocytes (CTLs) against target cells and this method is still being used in many laboratories. However, a major drawback ...

متن کامل

Visualization of Leishmania tropica Infection in BALB/c Mice by Bioluminescence Imaging

Background: Leishmania tropica is the cause of more than one form of leishmaniasis and lacks a known reservoir animal. This study compares the potential infectivity of recombinant and wild-type L. tropica in BALB/c mice. Methods: The potential infectivity of recombinant L. tropicaEGFP or L. tropicaEGFP-LUC by two different, the subcutaneous and intradermal, routes was compared using a range of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014