Optimization of collimator parameters to reduce rectal dose in intensity-modulated prostate treatment planning.
نویسندگان
چکیده
The inability to avoid rectal wall irradiation has been a limiting factor in prostate cancer treatment planning. Treatment planners must not only consider the maximum dose that the rectum receives throughout a course of treatment, but also the dose that any volume of the rectum receives. As treatment planning techniques have evolved and prescription doses have escalated, limitations of rectal dose have remained an area of focus. External pelvic immobilization devices have been incorporated to aid in daily reproducibility and lessen concern for daily patient motion. Internal immobilization devices (such as the intrarectal balloon) and visualization techniques (including daily ultrasound or placement of fiducial markers) have been utilized to reduce the uncertainty of intrafractional prostate positional variation, thus allowing for minimization of treatment volumes. Despite these efforts, prostate volumes continue to abut portions of the rectum, and the necessary volume expansions continue to include portions of the anterior rectal wall within high-dose regions. The addition of collimator parameter optimization (both collimator angle and primary jaw settings) to intensity-modulated radiotherapy (IMRT) allows greater rectal sparing compared to the use of IMRT alone. We use multiple patient examples to illustrate the positive effects seen when utilizing collimator parameter optimization in conjunction with IMRT to further reduce rectal doses.
منابع مشابه
The Relationship between the Different Prostate Intensity Modulated Radiation Therapy Techniques and Patient’s Anatomical Parameters
Introduction: Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Different IMRT methods can apply for irradiating the prostate, but there is not clear that which of these methods can provide better dose distribution for each patient individually. Therefore, the aim of this study was to evaluate the relationship between the different prosta...
متن کاملMonte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study
Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...
متن کاملOptimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective
Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives. Material...
متن کاملIterative Approach for Automatic Beam Angle Selection in Intensity Modulated Radiation Therapy Planning
Introduction: Beam-angle optimization (BAO) is a computationally intensive problem for a number of reasons. First, the search space of the solutions is huge, requiring enumeration of all possible beam orientation combinations. For example, when choosing 4 angles out of 36 candidate beam angles, C36 = 58905 possible combinations exist. Second, any change in a beam 4 config...
متن کاملDesign, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy
Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical dosimetry : official journal of the American Association of Medical Dosimetrists
دوره 30 4 شماره
صفحات -
تاریخ انتشار 2005