Calibration of Non-Conventional Imaging Systems

نویسندگان

  • Aubrey Keith Dunne
  • Paul F. Whelan
چکیده

This thesis investigates the calibration of cameras that do not conform to the standard pinhole-plus-distortion camera model. The ability to calibrate such camera systems is essential for the development of new, non-conventional, camera types. The major contributions of the thesis are the development of calibration algorithms for both central catadioptric cameras and non-central flexible mirror imaging systems. A key link between the calibrations of pinhole cameras and of general central cameras is expounded, upon which the proposed central calibration scheme is built. The proposed scheme incorporates constraints inherent to the geometry of central cameras, resulting in a method that is shown through rigorous experimentation to have superior performance to the standard generic method. An enabler for this calibration scheme is the use of active calibration grids, using structured light techniques, in place of standard calibration targets. An implementation and thorough characterisation of these active grids is presented. Nevertheless, the extraction of static calibration grid feature points from images with large distortions is still fundamentally important, in particular for experimentation with real images. To this end, a novel algorithm for the detection and consistent ordering of corners in such images of chessboard calibration grids is presented, and its capabilities are demonstrated. The flexible mirror imaging system investigated in this thesis consists of a fixed perspective camera viewing a deformable mirrored surface, which in general results in a non-central imager. A novel calibration technique is proposed that can model the flexibility of these systems, resulting in a calibration that is dynamically updated as the reflective surface flexes. Comprehensive testing for both constrained and unconstrained mirror deflections demonstrates that good calibration results can be obtained using this technique. Results for structure-from-motion and object reconstruction from a sequence of images from a calibrated flexible mirror camera are presented, establishing the capabilities of such calibrated non-conventional imaging systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Real Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation

Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research t...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Magnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems

In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...