Identification of echocardiographic "smoke" in a bench model with transcranial Doppler ultrasound.

نویسندگان

  • Y Yang
  • D G Grosset
  • Q Li
  • K R Lees
چکیده

BACKGROUND AND PURPOSE Spontaneous echo contrast in cardiac chamber has been indicated as a source of cerebral embolism. The nature of the echocardiographic smokelike signal is still not fully understood. This study was designed to regenerate spontaneous echo contrast and verify its thromboembolic characters in an in vitro model. METHODS Spontaneous echo contrast was reproduced in an expansion chamber under low flow conditions in a close circulation system. The spontaneous echo contrast was monitored and recorded with a 2-dimensional cardiosonography system and a transcranial Doppler device. Meanwhile, clinically commonly encountered embolic materials such as whole-blood clots, platelet aggregate-rich plasma, air bubbles, and 100-mL normal saline were injected into this monitored circuit. The differentiation of spontaneous echo contrast from emboli was performed by both visual observations of the echo images and offline Doppler signal intensity analysis. Average signal intensities produced by spontaneous contrast and injection of embolic materials and saline were compared. Furthermore, the effect of Doppler-detected flow velocity on generation of spontaneous contrast was also evaluated. RESULTS Spontaneous echo contrast was reproduced at low flow settings (90 to 120 mL/min) in this model. There was no significant difference in average signal intensity between the flow with spontaneous echo contrast and that without the echo (P=0.71). However, injection of embolic materials or normal saline did not generate smokelike image but caused much higher average signal intensity than the flow with spontaneous contrast (P<0.001). Injection of normal saline also increased average signal intensity. CONCLUSIONS Our results suggest that smokelike echo is a special echo phenomenon occurring at low flow situations and does not itself produce material capable of embolizing into the systemic circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency of Opium Addiction with Ischemic Stroke Patients and Comparing Their Cerebrovascular Doppler Ultrasound Alternations to Non-Addicts

Background: Ischemic stroke is a major cause of mortality and morbidity worldwide. Various studies on the etiology of this disease are in progress. Some studies have suggested that opium abuse may is associated with increased risk of ischemic stroke. The present study aimed to analyze the frequency of opium addiction and to compare cerebrovascular ultrasound patients’ changes to non-addicts. Me...

متن کامل

Detection of paradoxical cerebral echo contrast embolization by transcranial Doppler ultrasound.

Contrast echocardiography has been shown to be a sensitive method for detecting patent foramen ovale in embolic stroke, implying paradoxical embolization. However, not all two-dimensional echocardiographic studies are of diagnostic quality, and direct evidence for paradoxical cerebral embolization remains lacking. We addressed these problems by simultaneously using transcranial Doppler ultrasou...

متن کامل

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

Doppler echocardiographic assessment of fetal descending aortic and umbilical blood flows. Validation studies in fetal lambs.

BACKGROUND Doppler ultrasound has been used to assess abdominal aortic and umbilical blood flows in the human fetus, but the accuracy of this approach has not been demonstrated in an animal model. METHODS AND RESULTS We compared abdominal aortic and umbilical blood flows determined by Doppler echocardiography in 12 fetal lambs with invasive flow measurements using radionuclide-labeled microsp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2000