Reference point indentation is not indicative of whole mouse bone measures of stress intensity fracture toughness

نویسندگان

  • Alessandra Carriero
  • Jan L. Bruse
  • Karla J. Oldknow
  • José Luis Millán
  • Colin Farquharson
  • Sandra J. Shefelbine
چکیده

Bone fragility is a concern for aged and diseased bone. Measuring bone toughness and understanding fracture properties of the bone are critical for predicting fracture risk associated with age and disease and for preclinical testing of therapies. A reference point indentation technique (BioDent) has recently been developed to determine bone's resistance to fracture in a minimally invasive way by measuring the indentation distance increase (IDI) between the first and last indentations over cyclic indentations in the same position. In this study, we investigate the relationship between fracture toughness KC and reference point indentation parameters (i.e. IDI, total indentation distance (TID) and creep indentation distance (CID)) in bones from 38 mice from six types (C57Bl/6, Balb, oim/oim, oim/+, Phospho1(-/-) and Phospho1 wild type counterpart). These mice bone are models of healthy and diseased bone spanning a range of fracture toughness from very brittle (oim/oim) to ductile (Phospho1(-/-)). Left femora were dissected, notched and tested in 3-point bending until complete failure. Contralateral femora were dissected and indented in 10 sites of their anterior and posterior shaft surface over 10 indentation cycles. IDI, TID and CID were measured. Results from this study suggest that reference point indentation parameters are not indicative of stress intensity fracture toughness in mouse bone. In particular, the IDI values at the anterior mid-diaphysis across mouse types overlapped, making it difficult to discern differences between mouse types, despite having extreme differences in stress intensity based toughness measures. When more locations of indentation were considered, the normalised IDIs could distinguish between mouse types. Future studies should investigate the relationship of the reference point indentation parameters for mouse bone in other material properties of the bone tissue in order to determine their use for measuring bone quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of viscoelastic and plastic properties of polymers using indentation

Indentation methodologies are gaining popularity as they provide means of local property estimation, utilize smaller sample sizes, and do not destroy specimens. Classically, indentation has been used to measure hardness and Young’s modulus [1], but researchers have also proposed ways of predicting stress–strain curves [2], yield strength [3], and fracture toughness [3]. Different indentation te...

متن کامل

A methodology for the investigation of toughness and crack propagation in mouse bone.

Bone fracture is a health concern for those with aged bone and brittle bone diseases. Mouse bone is widely used as a model of human bone, especially to investigate preclinical treatment strategies. However, little is known about the mechanisms of mouse bone fracture and its similarities and differences from fracture in human bone. In this work we present a methodology to investigate the fractur...

متن کامل

Mixed Mode Fracture in Reinforced Concrete with Low Volume Fraction of Steel Fibers

An investigation into the mixed mode fracture of steel fiber reinforced concrete (SFRC)beams with one percent volume fraction of steel fiber is presented. A series of notched beams withdifferent notch depths and locations are tested under three-point bending. The test results for apparentfracture toughness, crack trajectories, and fracture energy are presented. The crack paths for SFRCand plain...

متن کامل

Reference Point Indentation of Human Trabecular Bone Treated with Bisphosphonates for Varying Durations

OF THESIS REFERENCE POINT INDENTATION OF HUMAN TRABECULAR BONE TREATED WITH BISPHOSPHONATES FOR VARYING DURATIONS Reference point indentation (RPI), a novel form of micro-indentation, quantifies RPI material parameters which correlate with modulus, yield stress, strength, or toughness. Information linking bisphosphonate treatment length with the material properties of osteoporotic trabecular bo...

متن کامل

Assessment of osteonal and interstitial bone quality using a novel custom-made microscope-indenter assembly

INTRODUCTION: Prediction of bone fracture goes beyond bone mineral density measurement. The quality of bone matrix is instrumental in providing fracture resistance to bone. Thus assessment of bone quality is critical to understanding bone fracture. Reference point indentation (RPI) purports to measure bone matrix quality in vivo and has been shown to separate fracture and non-fracture groups wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2014