Increased rates of wound complications with locking plates in distal fibular fractures.

نویسندگان

  • T Schepers
  • E M M Van Lieshout
  • M R De Vries
  • M Van der Elst
چکیده

INTRODUCTION There is a growing use of locking compression plates in fracture surgery. The current study was undertaken to investigate the wound complication rates of locking versus non-locking plates in distal fibular fractures. PATIENTS AND METHODS During a 6-year study period all consecutive, closed distal fibular fractures treated with either a locking or a non-locking plate were included and retrospectively analysed for complication related to the fibula. RESULTS A total of 165 patients received a one-third tubular plate and 40 patients were treated with a locking plate. The two groups were comparable with respect to patient characteristics (age, gender, smokers and diabetics), injury characteristics (affected side, fracture dislocations, number of fractured malleoli and classification) and operation characteristics (surgical delay and duration, use of a tourniquet and plate length). The wound complication rate was 5.5% in the conventional plating group, and 17.5% in the locking plate group (p=0.019). This difference was largely due to an increase in major complications, for which removal of the plate was necessary (p=0.008). CONCLUSION There is a significant increase in wound complications in distal fibular fractures treated with a locking compression plate. In light of the current study, we would caution against the application of the currently used locking compression plates in the treatment of distal fibular fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...

متن کامل

A locking contoured plate for distal fibular fractures: mechanical evaluation in an osteoporotic bone model using screws of different length.

Osteoporotic bone with poor mechanical capacity provides limited stability after fixation of ankle fractures. Stabilization with an implant providing increased fixation strength in osteoporotic bone could reduce failure rates of fixation and allow a more functional treatment. The purpose of this study was to evaluate a locking contoured plate for fixation of distal fibular fractures in comparis...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia

Background:  Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis  (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...

متن کامل

A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures

BACKGROUND A lateral approach with open reduction and internal fixation with a plate is a very effective technique for the majority of distal fibular fractures. However, this open approach for ankle fixation may be complicated by wound dehiscence and infection, especially in high-risk patients. An alternative to plating is an intramedullary implant, which allows maintenance of length, alignment...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 42 10  شماره 

صفحات  -

تاریخ انتشار 2011