Are ICD recipients able to foresee if they want to withdraw therapy or deactivate defibrillator shocks?☆

نویسندگان

  • Ingela Thylén
  • Debra K. Moser
  • Misook L. Chung
  • Jennifer Miller
  • Christina Fluur
  • Anna Strömberg
چکیده

Background Expert consensus statements on management of implantable cardioverter defibrillators (ICDs) emphasize the importance of having discussions about deactivation before and after implantation. These statements were developed with limited patient input. The purpose of this study was to identify the factors associated with patients' experiences of end-of-life discussions, attitudes towards such discussions, and attitudes towards withdrawal of therapy (i.e., generator replacement and deactivation) at end-of-life, in a large national cohort of ICD-recipients. Methods We enrolled 3067 ICD-patients, administrating the End-of-Life-ICD-Questionnaire. Results Most (86%) had not discussed ICD-deactivation with their physician. Most (69%) thought discussions were best at end-of-life, but 40% stated that they never wanted the physician to initiate a discussion. Those unwilling to discuss deactivation were younger, had experienced battery replacement, had a longer time since implantation, and had better quality-of-life. Those with psychological morbidity were more likely to desire a discussion about deactivation. Many patients (39%) were unable to foresee what to decide about deactivation in an anticipated terminal condition. Women, those without depression, and those with worse ICD-related experiences were more indecisive about withdrawal of therapy. Irrespective of shock experiences, those who could take a stand regarding deactivation chose to keep shock therapies active in many cases (39%). Conclusions Despite consensus statements recommending discussions about ICD-deactivation at the end-of-life, such discussion usually do not occur. There is substantial ambivalence and indecisiveness on the part of most ICD-patients in this nationwide survey about having these discussions and about expressing desires about deactivation in an anticipated end-of-life situation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deactivation of implantable cardioverter-defibrillators: results of patient surveys.

AIMS The indications for implantable cardioverter-defibrillators (ICDs) have been expanding, especially for primary prevention of sudden cardiac death. Implantable cardioverter-defibrillator saves lives; however, in near end-of-life situations linked to incurable diseases, the question arises as to whether or not to turn off the ICD to avoid excessive numbers of shocks as the heart begins to fa...

متن کامل

Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks.

BACKGROUND Implantable cardioverter defibrillator (ICD) use reduces mortality in patients with serious ventricular arrhythmias compared with antiarrhythmic drug (AAD) use. However, the relative impact of these therapies on self-perceived quality of life (QoL) is unknown. METHODS AND RESULTS Three self-administered instruments were used to measure generic and disease-specific QoL in Antiarrhyt...

متن کامل

Psychological indices as predictors for phantom shocks in implantable cardioverter defibrillator recipients.

BACKGROUND A phantom shock-the sensation of an implantable cardioverter defibrillator (ICD) discharge in the absence of an actual discharge-is a phenomenon that can occur in ICD patients. Little is known about the influence of psychological factors on the incidence of phantom shocks. We evaluated psychological correlates of phantom shocks 2 years post-ICD implant in a cohort of Dutch ICD recipi...

متن کامل

Predictors of implantable cardioverter defibrillator shocks during the first year.

The purpose of this study was to predict implantable cardioverter defibrillator (ICD) shocks using demographic and clinical characteristics in the first year after implantation for secondary prevention of cardiac arrest. A prospective design was used to follow 168 first-time ICD recipients over 12 months. Demographic and clinical data were obtained from medical records at the time of ICD insert...

متن کامل

Filling the need for new antiarrhythmic drugs to prevent shocks from implantable cardioverter defibrillators.

The implantable cardioverter defibrillator (ICD) has had an enormous impact on the treatment of patients with lifethreatening ventricular arrhythmias. It has been shown not only to be effective in reducing mortality in patients who have survived a potentially life-threatening ventricular arrhythmia (1) but also to improve outcomes when used as primary prevention for sudden cardiac death in pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2013