Evaluation of Bio-Rad D-100 HbA1c analyzer against Tosoh G8 and Menarini HA-8180V
نویسندگان
چکیده
OBJECTIVES To evaluate the Bio-Rad D-100®, an HPLC analyzer for glycated hemoglobin (HbA1c) determination, and to compare its performance with the Menarini HA-8180V® and Sysmex G8®. METHODS Method comparison was performed according to Clinical and Laboratory Standards Institute (CLSI) EP9-A2 guidelines. We selected 100 samples from the routine laboratory workload and analyzed them in duplicate with the three analyzers. The imprecision study was performed according to CLSI EP5-A2 guidelines for both inter-assay and intra-assay variability. Bias was assessed with external quality control material. To establish linearity, CLSI EP6-A protocol was followed. RESULTS Method comparison (95% confidence intervals in parentheses): D-100 vs G8: Passing-Bablok regression; y=0.973(0.963-0.983)×-0.07(-0.07-0.069); r=0.9989. Bland-Altman mean difference: -0.229%HbA1c (-0.256: -0.202); Relative bias plot: D-100/G8 vs D100-G8 mean ratio=0.971(0.967-0.975). D-100 vs HA-8180V: Passing-Bablok regression; y=0.944(0.932-0.958)×-0.078(0.024-0.173); r=0.9989. Bland-Altman mean difference: -0.363%HbA1c (-0.401: -0.325); Relative bias plot D-100/HA-8180V vs D100-HA-8180V mean ratio=0.955(0.952-0.958). Inter-assay coefficient of variation (CV): 0.81%. Intra-assay CV: 1.04% (low level), and 0.78% (high level). Bias against target value=2.332%. Linearity: r2=0.998 in the concentration range 4.4-13.9%HbA1c. Carry-over: 0.0024%. CONCLUSIONS The Bio-Rad D-100 shows good correlation with G8 and HA-8180V. There is a small proportional systematic difference (2.7% and 5.6%, respectively) in both comparisons. Inter and intra-assay CVs are both lower than the lowest CV obtained in studies performed with D-100 and other instruments.
منابع مشابه
Effects of hemoglobin C, D, E and S traits on measurements of hemoglobin A1c by twelve methods.
BACKGROUND Hemoglobin C, D Punjab, E or S trait can interfere with hemoglobin A1c (HbA1c) results. We assessed whether they affect results obtained with 12 current assay methods. METHODS Hemoglobin AA (HbAA), HbAC, HbAD Punjab, HbAE and HbAS samples were analyzed on one enzymatic, nine ion-exchange HPLC and two Capillary Electrophoresis methods. Trinity ultra(2) boronate affinity HPLC was the...
متن کاملIncidental findings of variant hemoglobin during hemoglobin A(1c) testing.
A variant hemoglobin fraction may be an incidental finding during HbA(1c) analysis using the G8 Tosoh HPLC analyzer, but it is unclear if the retention times and fraction patterns can reliably predict the findings of a high-performance liquid chromatography (HPLC) β-thalassemia program (Bio Rad Variant II analyzer). We chose 100 samples sent for HbA(1c) determinations (G8 Tosoh) with an inciden...
متن کاملComparison of IFCC-calibrated HbA(1c) from laboratory and point of care testing systems.
OBJECTIVE WHO, IDF and ADA recommend HbA(1c) ≥6.5% (48 mmol/mol) for diagnosis of diabetes with pre-diabetes 6.0% (42 mmol/mol) [WHO] or 5.7% (39 mmol/mol) [ADA] to 6.4% (47 mmol/mol). We have compared HbA(1c) from several methods for research relating glycaemic markers. RESEARCH DESIGN AND METHODS HbA1c was measured in EDTA blood from 128 patients with diabetes on IE HPLC analysers (Bio-Rad ...
متن کاملCorrection: evaluation of the Menarini-Arkray HA 8140 hemoglobin A1c analyzer.
To the Editor: John et al. (1) have evaluated the performance of the Menarini-Arkray HbA1c analyzer and have shown correlations of results on patient samples with the Bio-Rad Variant analyzer, an in-house HPLC method, a latex particle immunoassay, and an affinity chromatography method. The y 5 x lines in Fig. 2, b and d, do not appear to be in the correct position, probably because the x and y ...
متن کاملA comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA1c determination
INTRODUCTION Haemoglobin A1c (HbA1c) is widely used in the management of diabetes. Therefore, the reliability and comparability among different analytical methods for its detection have become very important. MATERIALS AND METHODS A comparative evaluation of the analytical performances (precision, linearity, accuracy, method comparison, and interferences including bilirubin, triglyceride, cho...
متن کامل