Peri-implant tissue is an important niche for Staphylococcus epidermidis in experimental biomaterial-associated infection in mice.

نویسندگان

  • Corine A N Broekhuizen
  • Leonie de Boer
  • Kim Schipper
  • Christopher D Jones
  • Shan Quadir
  • Roger G Feldman
  • Jacob Dankert
  • Christina M J E Vandenbroucke-Grauls
  • Jan J Weening
  • Sebastian A J Zaat
چکیده

Biomaterial-associated infections (BAI), which are predominantly caused by Staphylococcus epidermidis, are a significant problem in modern medicine. Biofilm formation is considered the pivotal element in the pathogenesis, but in previous mouse studies we retrieved S. epidermidis from peri-implant tissue. To assess the kinetics and generality of tissue colonization, we investigated BAI using two S. epidermidis strains, two biomaterials, and two mouse strains. With small inocula all implants were culture negative, whereas surrounding tissues were positive. When higher doses were used, tissues were culture positive more often than implants, with higher numbers of CFU. This was true for the different biomaterials tested, for both S. epidermidis strains, at different times, and for both mouse strains. S. epidermidis colocalized with host cells at a distance that was >10 cell layers from the biomaterial-tissue interface. We concluded that in mouse experimental BAI S. epidermidis peri-implant tissue colonization is more important than biofilm formation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microscopic detection of viable Staphylococcus epidermidis in peri-implant tissue in experimental biomaterial-associated infection, identified by bromodeoxyuridine incorporation.

Infection of biomedical devices is characterized by biofilm formation and colonization of surrounding tissue by the causative pathogens. To investigate whether bacteria detected microscopically in tissue surrounding infected devices were viable, we used bromodeoxyuridine (BrdU), a nucleotide analogue that is incorporated into bacterial DNA and can be detected with antibodies. Infected human tis...

متن کامل

68Ga-DOTA-Siglec-9 PET/CT imaging of peri-implant tissue responses and staphylococcal infections

BACKGROUND Staphylococcus epidermidis (S. epidermidis) has emerged as one of the leading pathogens of biomaterial-related infections. Vascular adhesion protein-1 (VAP-1) is an inflammation-inducible endothelial molecule controlling extravasation of leukocytes. Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a leukocyte ligand of VAP-1. We hypothesized that (68)Ga-labeled 1,4,7,10...

متن کامل

In Vitro Interactions between Bacteria, Osteoblast-Like Cells and Macrophages in the Pathogenesis of Biomaterial-Associated Infections

Biomaterial-associated infections constitute a major clinical problem that is difficult to treat and often necessitates implant replacement. Pathogens can be introduced on an implant surface during surgery and compete with host cells attempting to integrate the implant. The fate of a biomaterial implant depends on the outcome of this race for the surface. Here we studied the competition between...

متن کامل

Interleukin-1 receptor type I gene-deficient mice are less susceptible to Staphylococcus epidermidis biomaterial-associated infection than are wild-type mice.

Elevated concentrations of interleukin-1 (IL-1) were found in tissue surrounding biomaterials infected with Staphylococcus epidermidis. To determine the role of IL-1 in biomaterial-associated infection (BAI), IL-1 receptor type I-deficient (IL-1R(-/-)) and wild-type mice received subcutaneous implants of silicon elastomer (SE) or polyvinylpyrrolidone-grafted SE (SEpvp), combined with an injecti...

متن کامل

Enhanced susceptibility to subcutaneous abscess formation and persistent infection around catheters is associated with sustained interleukin-1beta levels.

A persistent Staphylococcus epidermidis infection in mice around a subcutaneous polyvinylpyrrolidone-grafted silicon elastomer catheter (SEpvp) but not around a conventional silicon elastomer catheter was observed. With SEpvp pericatheter tissue, protracted and exaggerated interleukin-1beta (IL-1beta) production was found. Apparently, sustained levels of IL-1beta are associated with enhanced su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infection and immunity

دوره 75 3  شماره 

صفحات  -

تاریخ انتشار 2007