[Impact of iterative reconstruction on shape reproducibility of three-dimensional computed tomography].

نویسندگان

  • Takashi Hoshino
  • Katsuhiro Ichikawa
  • Syouichi Terakawa
  • Yasuyuki Katsuma
  • Ichirou Fujimura
  • Yuuji Ueda
  • Youhei Miura
  • Kenji Nishimura
چکیده

The purpose of this study was to evaluate the effect of an iterative reconstruction method (IR) on shape reproducibility in three-dimensional (3D) computed tomography images. We used an IR (sinogram-affirmed iterative reconstruction: SAFIRE) implemented in a 64-channel multi slice computed tomography system (Siemens, SOMATOM Definition AS). We scanned a simulated vessel phantom with 180-HU vessel contrast at various radiation doses and reconstructed axial images of filtered back projection (FBP) and SAFIRE. Then we reconstructed multi-planar reconstruction (MPR) and volume rendering (VR) images from the axial images. Roundness was evaluated from MPR images and vessel surface roughness was evaluated from pixel value profiles of a vessel in VR images and visual evaluation by radiological technologists. In comparison on equivalent dose, the roundness and roughness were improved with increase of SAFIRE strength level. However, in comparison on equivalent noise (standard deviation: SD) of axial images, SAFIRE strength levels of 2 to 5 were significantly inferior to FBP (p<0.05). SAFIRE strength of 1 with a dose reduction of 19% maintained the shape reproducibility in all evaluations. Therefore, it would be not appropriate to use the SD of axial image as index for the dose reduction rate determination of 3D-CT images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 68 12  شماره 

صفحات  -

تاریخ انتشار 2012