Subconjunctival Air Leakage After Descemet's Stripping Automated Endothelial Keratoplasty(DSAEK) in a Post-Trabeculectomy Eye

نویسندگان

  • Takeshi Ide
  • Sonia H Yoo
  • Theodore Leng
  • Terrence P O’Brien
چکیده

PURPOSE To report a case of subconjunctival air leakage from the anterior chamber (AC) into a trabeculectomy bleb after Descemet's stripping automated endothelial keratoplasty (DSAEK). METHODS An 89 year-old woman with a previous history of primary open angle glaucoma in her left eye and previous trabeculectomy with mitomycin C had DSAEK on the patient's left eye in order to treat her endothelial disease. During the DSAEK procedure, air was injected into the AC to aid in graft adherence. RESULTS The day after the surgery, subconjunctival air leakage from the AC into a trabeculectomy bleb was observed. CONCLUSIONS Although our patient did not have any complications from this leak, there exists the potential for hypotony, bleb-related infections, and dislocations of the DSAEK graft. Given the potential consequences, these patients should be monitored closely.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subconjunctival Emphysema After Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)

DSAEK has recently evolved as a preferred method in place of PKP. After DSAEK, we experienced subconjunctival emphysema, decreased air bubble in the AC and low IOP. This could lead to complications, higher rate of dislocation or infection. We should control the wound closure with suture when in doubt.

متن کامل

Increased Rates of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Failure and Dislocation in Glaucomatous Eyes with Aqueous Shunts

PURPOSE To investigate the rates of Descemet's stripping automated endothelial keratoplasty (DSAEK) graft dislocation and failure in glaucomatous eyes, including eyes with history of trabeculectomy and/or aqueous shunts. METHODS A retrospective, case-control study on a total of 424 consecutive eyes undergoing DSAEK at an academic setting compared 96 glaucomatous eyes to a control group of 328...

متن کامل

Descemet's stripping with automated endothelial keratoplasty and glaucoma.

PURPOSE OF REVIEW Descemet's stripping with automated endothelial keratoplasty (DSAEK) has recently become the preferred surgical procedure replacing penetrating keratoplasty (PKP) for corneal endothelial disorders. However, DSAEK may also be associated with postprocedure intraocular pressure elevation and secondary glaucoma, and presents unique surgical challenges in patients with preexisting ...

متن کامل

Descemet's Stripping Automated Endothelial Keratoplasty versus Descemet's Membrane Endothelial Keratoplasty in the Fellow Eye for Fuchs Endothelial Dystrophy: A Retrospective Study

AIM To evaluate visual outcome and endothelial cell density (ECD) after Descemet's Membrane Endothelial Keratoplasty (DMEK) in comparison with Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) in the fellow eye for Fuchs endothelial dystrophy (FED). DESIGN Single-centre, retrospective case series. METHODS 30 eyes of 30 patients undergoing DMEK, who completed a 1-year follow-up...

متن کامل

Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries

Purpose Descemet's stripping automated endothelial keratoplasty (DSAEK) is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP). We report a new method that uses ophthalmic viscoelastic devices (OVDs) to achieve good graft adhesion. Case Presentation We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009