Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures

نویسندگان

  • Chih-Kun Hsiao
  • Yi-Jung Tsai
  • Cheng-Yo Yen
  • Cheng-Hung Lee
  • Teng-Yao Yang
  • Yuan-Kun Tu
چکیده

BACKGROUND Proximal humeral fractures treated with locking plate can fail due to varus collapse, especially in osteoporotic bone with medial cortex comminution. The use of an intramedullary strut together with locking plate fixation may strengthen fixation and provide additional medial support to prevent the varus malalignment. This study biomechanically investigates the influence of an intramedullary cortical bone strut on the cyclic stability of proximal humeral fractures stabilized by locking plate fixation in a cadaver model. METHODS Ten cadaveric humeri were divided into two groups statistically matched for bone density. Each specimen was osteotomized with 10 mm gap at the surgical neck. The non-augmented group stabilized with locking plate alone; in the augmented group, a locking plate was used combined with an intramedullary cortical bone strut. The strut was retrograded into the subchondral bone, and three humeral head screws were inserted into the strut to form a plate-screw-strut mechanism. The cyclic axial load was performed to 450 N for 6000 cycles and then loaded to failure. Construct stiffness, cyclic loading behavior and failure strength were analyzed to identify differences between groups. RESULTS The augmented constructs were significantly stiffer than the non-augmented constructs during cycling. On average, the maximum displacements at 6000 cycles for non-augmented and augmented groups were 3.10 ± 0.75 mm and 1.7 ± 0.65 mm (p = 0.01), respectively. The mean peak-to-peak (inter cycle) displacement at 6000 cycles was about 2 times lower for the augmented group (1.36 ± 0.68 mm vs. 2.86 ± 0.51 mm). All specimens showed varus collapse combined with loss of screw fixation of the humeral head. The failure load of the augmented group was increased by 2.0 (SD = 0.41) times compared with the non-augmented group (p < 0.001). CONCLUSIONS The stability and strength of the locking plate augmented with an intramedullary strut were significantly increased. For bone with poor quality, the subsidence of the locked screws led larger displacement, decreased the stability of the constructs, however, the plate-screw-strut mechanism provided more rigidity to stabilize the fixation. This study emphasized the importance of intramedullary support for the proximal humeral fractures fixed with a locked plate under cyclic loading, especially in bone with poor quality. This work is based on the results of cadaver model, further in vivo analysis is necessary to determine if the clinical results can be extrapolated from this data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The management of complex periprosthetic humeral fractures: a case series of strut allograft augmentation, and a review of the literature

There is little published discussion on the management of postoperative periprosthetic humeral fractures where rotator cuff function is poor, the bone stock is dwindling or both. This is a phenomenon increasingly seen in the older, more osteoporotic population and presents an interesting challenge especially in when faced with these patients with poor bone quality. We present the treatment of t...

متن کامل

Plating, nailing, external fixation, and fibular strut grafting for non-union of humeral shaft fractures.

PURPOSE To compare various treatment modalities (plating, Ilizarov external fixation, and non-vascular fibular cortical strut grafting) for non-union of humeral shaft fractures. METHODS Records of 9 women and 26 men aged 24 to 71 (mean, 42) years who presented with non-union of humeral shaft fractures were reviewed. The humeral shaft fractures were secondary to low-energy trauma (n=22) or veh...

متن کامل

Indices of risk assessment of fracture of the proximal humerus.

Osteoporotic fractures are now a social problem for incidence and costs. Fractures of the proximal humerus events are frequent and constantly increasing. It is estimated that they are 20% of all osteoporotic fractures. Bone densitometry in most cases underestimates the real humeral bone density.There is little information about osteoporotic changes in the proximal humerus and their association ...

متن کامل

Proximal humeral nonunions treated with fixed-angle locked plating and an intramedullary strut allograft.

OBJECTIVE To determine if the use of a fixed-angle locked plate plus an intramedullary allograft in the treatment of proximal humeral nonunions resulted in improved union. DESIGN Retrospective clinical analysis of patients' medical charts and radiographs. SETTING Clinical practice of senior authors. PATIENTS/PARTICIPANTS Eighteen patients who presented to the senior authors' clinic betwee...

متن کامل

Tension wiring to increase stability of conventional plating for proximal humeral fractures: An alternative to a locking plate

Fixation of comminuted or osteoporotic fractures in the proximal humerus is a challenge for orthopedic surgeons. In the past two decades, locking plates have been used for proximal humeral fracture fixation. However, complications such as loss of reduction have been reported, and the implants are not always available in some regions. Therefore, we describe an alternative procedure involving fix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017