Microcantilever based disposable viscosity sensor for serum and blood plasma measurements.
نویسندگان
چکیده
This paper proposes a novel method for measuring blood plasma and serum viscosity with a microcantilever-based MEMS sensor. MEMS cantilevers are made of electroplated nickel and actuated remotely with magnetic field using an electro-coil. Real-time monitoring of cantilever resonant frequency is performed remotely using diffraction gratings fabricated at the tip of the dynamic cantilevers. Only few nanometer cantilever deflection is sufficient due to interferometric sensitivity of the readout. The resonant frequency of the cantilever is tracked with a phase lock loop (PLL) control circuit. The viscosities of liquid samples are obtained through the measurement of the cantilever's frequency change with respect to a reference measurement taken within a liquid of known viscosity. We performed measurements with glycerol solutions at different temperatures and validated the repeatability of the system by comparing with a reference commercial viscometer. Experimental results are compared with the theoretical predictions based on Sader's theory and agreed reasonably well. Afterwards viscosities of different Fetal Bovine Serum and Bovine Serum Albumin mixtures are measured both at 23°C and 37°C, body temperature. Finally the viscosities of human blood plasma samples taken from healthy donors are measured. The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than 0.04 cP. The sample volume requirement is less than 150 μl and can be reduced significantly with optimized cartridge design. Both the actuation and sensing are carried out remotely, which allows for disposable sensor cartridges.
منابع مشابه
Microrheological Coagulation Assay Exploiting Micromechanical Resonators.
Rheological measurements in biological liquids yield insights into homeostasis and provide information on important molecular processes that affect fluidity. We present a fully automated cantilever-based method for highly precise and sensitive measurements of microliter sample volumes of human blood plasma coagulation (0.009 cP for viscosity range 0.5-3 cP and 0.0012 g/cm3 for density range 0.9...
متن کاملMicrocantilever Based Loc System for Coagulation Measurements
In this paper, a microcantilever-based system enabling multiple coagulation tests on the same disposable cartridge is demonstrated. The system consists of independent cartridge and reader unit. The actuation of the nickel cantilevers is conducted remotely with an external electro-coil and remote optical read-out is utilized for sensing. Both Prothrombin Time (PT) and activated Partial Thrombopl...
متن کاملA viscosity-dependent affinity sensor for continuous monitoring of glucose in biological fluids.
We present a viscometric affinity biosensor for continuous monitoring of glucose in biological fluids such as blood and plasma. The sensing principle of this chemico-mechanical sensor is based upon the viscosity variation of a sensitive fluid with glucose concentration. Basically, this device includes both an actuating and a sensing piezoelectric diaphragms as well as a flow-resistive microchan...
متن کاملDistribution of blood viscosity values and biochemical correlates in healthy adults.
Increases in the viscosity of blood and plasma predict clinical manifestations of atherothrombotic vascular disease. The clinical utility of viscosity measurements in cardiovascular risk factor analysis requires reference values established from a healthy disease-free population. A cohort of 126 (71 men, 55 women) healthy nonsmoking adults had fasting blood analysis after a 12-14-h fast. Viscos...
متن کاملElectrochemical Determination of Neonicotinoid Insecticide Clothianidin by Nanomaterial based Disposable Electrode
Disposable, selective and low-cost carbon nanotube modified electrodes were fabricated for the electrochemical detection of neonicotinoid insecticide, Clothianidin (CLT). Almost 2 folds’ increase at Clothianidin reduction signal was obtained by using single-walled carbon nanotube modified electrodes (SWCNT-PGE) compared to unmodified electrodes. These nanomaterials modified electrodes developed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Methods
دوره 63 3 شماره
صفحات -
تاریخ انتشار 2013