Use of a proximal humeral plate for a paediatric peri-prosthetic femoral fracture

نویسندگان

  • C.R. Shaw
  • J. Badhesha
  • G. Ayana
  • R. Abu-Rajab
چکیده

In this case an 18-year-old female with cerebral palsy sustained a peri-prosthetic femoral fracture adjacent to a blade plate previously inserted for a femoral varus osteotomy. The injury was treated using a long proximal humeral locking plate. The existing blade plate was removed. The fracture was reduced and held, and a 10-hole PHILOS™ plate applied with near anatomical reduction. There were no post-operative complications. Radiographic union was confirmed at 11 months. To our knowledge, this is the first reported use of a PHILOS™ plate in the management of a femoral peri-prosthetic fracture and successfully demonstrated a straightforward method for revision fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Managing extremely distal periprosthetic femoral supracondylar fractures of total knee replacements - a new PHILOS-ophy

We report two cases where a proximal humeral locking plate was used for the fixation of an extremely distal, type III peri-prosthetic femoral fractures in relation to a total knee replacement (TKR). In each case there was concern regarding the fixation that could be achieved using the available anatomic distal femoral plates due to the size and bone quality of distal fragment. The design of the...

متن کامل

The Kent hip prosthesis: an evaluation of 145 prostheses after a mean of 5.1 years.

The Kent hip is a distally-locked femoral stem which was developed to address severe proximal bone loss, severe bony deformity and peri-prosthetic fracture. We reviewed the results of 145 consecutive Kent hips implanted into 141 patients between 1987 and 2000. The indications for implantation were aseptic loosening (75 hips), septic loosening (two), peri-prosthetic and prosthetic fracture (37),...

متن کامل

Non-operative management of a peri-prosthetic subcapital fracture after metal-on-metal Birmingham hip resurfacing.

We describe a patient who sustained a peri-prosthetic fracture of the femoral neck two weeks after undergoing a resurfacing procedure for osteoarthritis of the hip. The fracture was minimally displaced and a satisfactory outcome was obtained following conservative treatment.

متن کامل

Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component.

Revision total hip arthroplasty (THA) is challenging when there is severe loss of bone in the proximal femur. The purpose of this study was to evaluate the clinical and radiographic outcomes of revision THA in patients with severe proximal femoral bone loss treated with a fluted, tapered, modular femoral component. Between January 1998 and December 2004, 92 revision THAs were performed in 92 pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014