[(18)F]Fluorodeoxyglucose positron emission tomography-computerized tomography and lung cancer: a significant referral bias exists.
نویسندگان
چکیده
OBJECTIVE [(18)F]Fluorodeoxyglucose positron emission tomography-computerized tomography (PET-CT) scan is a tool widely used in the diagnosis and staging of lung cancer. Referral bias is present when the results of a diagnostic study affect the decision to proceed with definitive testing. This bias artificially increases the sensitivity and decreases the specificity, and may inappropriately alter the decision to undergo definitive testing. The accuracy of PET-CT scan in suspected lung cancer and the role of referral bias were investigated. METHODS From January 2005 through June 2007, 584 consecutive patients undergoing PET-CT scan for suspected lung cancer were studied. Endpoints measured included qualitative and quantitative results of PET-CT scans and pathologic results from patients, who underwent invasive procedures for diagnosis, staging and/or therapy. A positive PET scan was defined as one in which the standard uptake value (SUV) was greater than 2.5. A standard mathematical model, based on overall results of PET-CT scan in all patients, was used to create adjustments to account for the effect of referral bias. RESULTS A total of 414 (71%) of PET-CT scans were reported as positive, while 170 (29%) were negative. Attempt at tissue diagnosis occurred in 417 patients (71%); surgical intervention was performed in 246 (42%). Whereas 86% (355/414) of patients with a positive PET-CT scan underwent tissue sampling, only 36% (62/170) with a negative PET-CT scan had an attempt (p<.001). In patients with a positive study, a higher SUV was associated with an attempt at tissue diagnosis (p<.001). Before adjustment, the sensitivity and specificity of the PET-CT scan for any cancer were 87% and 43%. After adjustment, sensitivity fell to 75%, while specificity rose to 64%. The unadjusted sensitivity of PET-CT scan for detecting mediastinal disease was only 79%. CONCLUSIONS The estimate of the accuracy of PET-CT scan is significantly influenced by referral bias, and a strong reliance is placed on its results. Furthermore, patients with a positive PET-CT scan are more likely to undergo tissue sampling as the SUV increases. Given the relatively low sensitivity of the PET-CT scan in detecting disease and its poor performance in the mediastinum, the PET-CT scan may have too high an impact on the decision to undergo further invasive diagnostic procedures. Patients should not be deferred from tissue sampling based solely on a negative PET-CT scan.
منابع مشابه
Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کاملPrognostic value of various metabolic parameters on pre-treatment 18-F-FDG PET/CT in patients with stage I-III non-small cell lung cancer
Background: the aim of this study was to investigate the prognostic value of 18Fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) parameters in both overall survival and progression-free survival in Stage I-III non-small cell lung cancer (NSCLC). Materials and Methods: In this retrospective study, 267 patients who were diagnosed as Stage I-III non-smal...
متن کاملDiagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...
متن کاملPredictive ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography for pathological complete response and prognosis after neoadjuvant chemotherapy in triple-negative breast cancer patients
Objective The mortality of patients with locally advanced triple-negative breast cancer (TNBC) is high, and pathological complete response (pCR) to neoadjuvant chemotherapy (NAC) is associated with improved prognosis. This retrospective study was designed and powered to investigate the ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) to predict pat...
متن کاملA case of lung cancer associated with pneumoconiosis diagnosed by fluorine-18 fluorodeoxyglucose positron emission tomography.
We report a case of lung cancer arising from progressive massive fibrosis (PMF) associated with pneumoconiosis. In this case, fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) was able to clearly distinguish the lung cancer from PMF, suggesting a potential usefulness of FDG-PET in cancer screening in patients with pneumoconiosis. To our knowledge, this is the first descripti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 39 4 شماره
صفحات -
تاریخ انتشار 2011