Probe interval designs that improve accuracy of CoMPACT monitor
نویسندگان
چکیده
We have proposed the CoMPACT monitor; it achieves the scalable measurement of the one-way delay distribution for each flow. CoMPACT monitor transforms the one-way delay data obtained by active measurement by using the passively monitored traffic data of the target flow. A recent study reported that using an inter-probe time with Gamma distribution can improve the accuracy of simple active measurements. The improvement is in terms of the ensemble mean of the stationary stochastic process. In this paper, to improve accuracy of CoMPACT monitor, we apply Gamma-probing as the active measurement component of CoMPACT monitor. The significant issue in this application is in the difference between objects targeted for measurement; CoMPACT monitor estimates the time average of sample path rather than the ensemble mean. We investigate the characteristics of CoMPACT monitor and Gamma-probing, and verify the improved accuracy of CoMPACT monitor through simulations. 2010 Elsevier B.V. All rights reserved.
منابع مشابه
Active/passive combination-type performance measurement method using change-of-measure framework
We propose a new method of performance measurement called the Change-of-Measure Based Passive/Active Monitoring (CoMPACT Monitor), in which estimates of the actual performance seen by users are obtained based on both active and passive measurement data. With this method, the performance experienced by an individual user, organization or application can be estimated from the results of scalable ...
متن کاملUniversal Approximation of Interval-valued Fuzzy Systems Based on Interval-valued Implications
It is firstly proved that the multi-input-single-output (MISO) fuzzy systems based on interval-valued $R$- and $S$-implications can approximate any continuous function defined on a compact set to arbitrary accuracy. A formula to compute the lower upper bounds on the number of interval-valued fuzzy sets needed to achieve a pre-specified approximation accuracy for an arbitrary multivariate con...
متن کاملAccuracy Improvement of CoMPACT Monitor by Using New Probing Method
CoMPACT monitor that we have proposed is new technique to measure per-flow quality of service (QoS). CoMPACT monitor provide scalable measurement of one-way delay distribution by the combination of active and passive measurement. Recently, a new probing method for improving the accuracy of simple active measurement have been proposed. In this paper, we adopt the new probing method as active mea...
متن کاملاندازهگیری ضریب شکست غیر خطی در شیشههای آلاییده به بلورهای نیمرسانا
There are several techniques in use for non-linear refractive index measurement, namely, interferometric techniques, in which conventional inter-ferometers are used, degenerate for wave mixing (DFWM), and z-scan, Each of these techniques suffers from some shortcmings. For example conventional interferometers like Fabry-Perot and Twyman-Green need high quality optical components, unwanted refl...
متن کاملA Compact Scheme for a Partial Integro-Differential Equation with Weakly Singular Kernel
Compact finite difference scheme is applied for a partial integro-differential equation with a weakly singular kernel. The product trapezoidal method is applied for discretization of the integral term. The order of accuracy in space and time is , where . Stability and convergence in norm are discussed through energy method. Numerical examples are provided to confirm the theoretical prediction ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Simulation Modelling Practice and Theory
دوره 19 شماره
صفحات -
تاریخ انتشار 2011