Effect of face mask design on inhaled mass of nebulized albuterol, using a pediatric breathing model.

نویسندگان

  • Hui-Ling Lin
  • Ruben D Restrepo
  • Douglas S Gardenhire
  • Joseph L Rau
چکیده

BACKGROUND Aerosol face mask design and the distance at which the face mask is held from the face affect the delivery of nebulized medication to pediatric patients. OBJECTIVE To measure the inhaled mass of nebulized albuterol with 3 types of pediatric face mask, at 3 different distances from the face, with a model of a spontaneously breathing infant. METHODS We compared a standard pediatric face mask and 2 proprietary pediatric face masks (one shaped to resemble a dragon face, the other shaped to resemble a fish face). The albuterol was nebulized with a widely used jet nebulizer. Aerosol delivery with each type of mask was measured with the mask at 0 cm (ie, mask directly applied to the mannequin face), 1 cm, and 2 cm from the mannequin face. In each test the nebulizer was filled with a 3-mL unit dose of albuterol sulfate and powered by oxygen at 8 L/min, with a total nebulization time of 5 min. The mannequin face was connected to a lung simulator that simulated a spontaneously breathing infant. We measured inhaled mass by collecting the aerosol on a 2-way anesthesia filter that was attached to the back of the mannequin's oral opening via a 15-mm silicon adapter. We also measured residual drug left in the nebulizer, and estimated the drug lost to the atmosphere. RESULTS The mean +/- SD inhaled percentage of the nominal dose values at 0 cm, 1 cm, and 2 cm, respectively, were 2.18 +/- 0.53%, 1.45 +/- 0.46%, and 0.92 +/- 0.51% with the standard mask; 2.65 +/- 0.55%, 1.7 +/- 0.38%, and 1.3 +/- 0.37% with the dragon mask; and 3.67 +/- 0.8%, 2.92 +/- 0.4%, and 2.26 +/- 0.56% with the fish mask. With all 3 masks there was a statistically significant difference (p < 0.001) in inhaled mass between the 0 cm and 2 cm distance. The fish mask had a significantly higher (p < 0.001) inhaled mass than the dragon mask or the standard mask, at all 3 distances. CONCLUSIONS The inhaled mass of albuterol is significantly reduced when the mask is moved away from the face. The fish mask had significantly higher inhaled mass than the standard mask or the dragon mask, under the conditions we studied. Mask design may affect nebulized albuterol delivery to pediatric patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

BACKGROUND Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The...

متن کامل

Is it time to say good bye to blow-by?

While it has been clearly demonstrated that spontaneously breathing children of all ages with bronchospasm respond well to nebulized bronchodilators, only a small proportion of aerosolized drug reaches the lungs. 1–9 In addition, the combination of a small airway diameter, a rapid breathing pattern, and poor tolerance to the treatment has made delivery of nebulized medications to the airway of ...

متن کامل

In Vitro Comparison of Aerosol Delivery Using Different Face Masks and Flow Rates With a High-Flow Humidity System.

BACKGROUND Aerosol drug delivery to infants and small children is influenced by many factors, such as types of interface, gas flows, and the designs of face masks. The purpose of this in vitro study was to evaluate aerosol delivery during administration of gas flows across the range used clinically with high-flow humidity systems using 2 aerosol masks. METHODS A spontaneous lung model was use...

متن کامل

Influence of nebulizer type with different pediatric aerosol masks on drug deposition in a model of a spontaneously breathing small child.

BACKGROUND The performance of nebulizers varies with the design type as well as the breathing patterns of various age groups. The present study quantified aerosol delivery using spontaneously breathing parameters of a small child (2-4 years) by a lung simulator to determine the influence of nebulizer type, actuation mechanisms, and pediatric aerosol masks. METHODS Three types of nebulizer (c...

متن کامل

An investigation of nebulized bronchodilator delivery using a pediatric lung model of spontaneous breathing.

BACKGROUND The literature lacks comparative data on nebulizer aerosol delivered via mask versus T-piece, to spontaneously breathing pediatric subjects. PURPOSE To compare total inhaled drug mass delivered via standard pediatric aerosol mask versus via T-piece, with increasing distance. METHODS We used a sample of 5 nebulizers, operated under manufacturers' conditions, with a standard pediat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2007