Integration of a nanoporous platinum thin film into a microfluidic system for non-enzymatic electrochemical glucose sensing.
نویسندگان
چکیده
In this paper, we describe an amperometric-type enzymeless glucose sensing system based on a nanoporous platinum (Pt) electrode embedded in a microfluidic chip. This microchip system is comprised of a microfluidic transport channel network and a miniaturized electrochemical cell for nonenzymatic glucose sensing. Sample and buffer solutions were transferred to the cell by programmed electroosmotic flow (EOF). A nanoporous Pt electrode with the roughness factor of 200.6 was utilized to determine glucose concentrations in phosphate buffered saline (PBS) by the direct oxidation of glucose, without any separation process. The sensitivity of the developed system is 1.65 microA cm-2 mM-1 in the glucose concentration range from 1-10 mM in PBS.
منابع مشابه
Fabrication and Optimization of a Nanoporous Platinum Electrode and a Non-enzymatic Glucose Micro-sensor on Silicon
In this paper, optimal conditions for fabrication of nanoporous platinum (Pt) were investigated in order to use it as a sensitive sensing electrode for silicon CMOS integrable non-enzymatic glucose micro-sensor applications. Applied charges, voltages, and temperatures were varied during the electroplating of Pt into the formed nonionic surfactant C16EO8 nano-scaled molds in order to fabricate n...
متن کاملDetermination of Captopril using platinum coated nanoporous gold film electrode
In this article electrochemical determination of captopril at the surface of the platinum coated nanoporous gold film (PtNPGF) electrode is reported using the cyclic voltammetry and amperometry. For the preparation of PtNPGF, the surface of NPGF electrode was covered with Cu layer using underpotential electrochemical deposition (UPD).Afterward, the copper layer is replaced with platinum ions vi...
متن کاملElectrochemical non-enzymatic glucose sensors.
The electrochemical determination of glucose concentration without using enzyme is one of the dreams that many researchers have been trying to make come true. As new materials have been reported and more knowledge on detailed mechanism of glucose oxidation has been unveiled, the non-enzymatic glucose sensor keeps coming closer to practical applications. Recent reports strongly imply that this p...
متن کاملA Microfluidic Device for Opto-Electrochemical Sensing
A microfluidic device that contains a silica film as optical transducer and electrochemical electrode was used to monitor how ferricyanide ion behaves within nanoporous matrix. This prototype device allows UV-VIS absorption spectroscopy and cyclic voltammetry to be performed at the same time. Significant reducing in leaching of redox molecules proved this device integrated with silica film can ...
متن کاملOne-Step to Prepare Self-Organized Nanoporous NiO/TiO2 Layers and its Use in Non-Enzymatic Glucose Sensing
A highly ordered nanoporous NiTi oxide layers were fabricated on Ti alloys with high Ni contents (50.6 at.%) by a combination of self-organizing anodization at 0°C and subsequent selective etching in H2O2. The key for successful formation of such layers is to sufficiently suppress the dissolve of NiO by applying lower temperature during anodization. The resulting nanoporous structure is connect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 23 3 شماره
صفحات -
تاریخ انتشار 2007