Comparison of the Effects of Heparin and 0.9% Sodium Chloride Solutions in Maintenance of Patency of Central Venous Catheters
نویسندگان
چکیده
BACKGROUND Occlusion of central venous catheters is one of the limiting factors in using them. Heparinized saline solution is the standard solution used for keeping the catheters open. OBJECTIVES This study aimed to determine the effect of heparin saline solution and normal saline in maintenance of patency of central venous catheters. PATIENTS AND METHODS This double-blind study was performed on 84 patients of intensive care unit who had central venous catheters. The patients were randomly divided into two groups of heparin saline receivers and normal saline receivers. In the heparin group after each drug injection into the lumen, 3 mL of heparin saline solution was injected in the catheter as well. The other group only received 10 mL of normal saline instead. The catheters were examined for blood return and flushing every eight hours for 21 days. Data was analyzed using SPSS software version 20 and descriptive and analytic statistics were studied. RESULTS There was no significant difference in the rate of flushing (P = 0.872) and possibility of taking blood samples from catheters (P = 0.745) in the two groups of heparin and normal saline receivers. Furthermore, using heparin had no effect on prolonging the survival of catheters. CONCLUSIONS Considering possible side effects of heparin and the increase in treatment charges and the fact that using heparin did not have a significant effect on patency and survival of catheters in the studied patients, it is recommended to use normal saline solution to maintain the patency of central venous catheters.
منابع مشابه
Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.
OBJECTIVE To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. DESIGN Single-center, randomized, open label trial. SETTING Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. PATIENTS Three hundred forty-one patients with multilumen...
متن کاملASHP therapeutic position statement on the institutional use of 0.9% sodium chloride injection to maintain patency of peripheral indwelling intermittent infusion devices.
0.9% Sodium chloride injection is a safe and effective indwelling solution for maintaining catheter patency of peripheral indwelling intermittent infusion devices (PIIIDs) in adults and children age one year or older. ASHP supports the use of 0.9% sodium chloride injection in preference to heparin-containing flush solutions (heparin flush) in the institutional setting, on the basis of clinical ...
متن کاملLocking solutions for hemodialysis catheters; heparin and citrate--a position paper by ASDIN.
There is wide variation in the use of solutions to "lock" or fill tunneled central venous catheters for dialysis. Some centers use undiluted heparin concentrations ranging from 1000 to 10,000 U/ml and other centers place from 1000 to 10,000 U per lumen. Based on available evidence, it appears that heparin 1000 U/ml, or 4% sodium citrate are suitable choices for lock solution to maintain patency...
متن کاملHeparinized and Saline Solutions in the Maintenance of Arterial and Central Venous Catheters After Cardiac Surgery
BACKGROUND Heparinized saline solution is used to prevent occlusion in the arterial catheters and central venous pressure monitoring catheters. Even at low dose, heparin administration can be associated with serious complications. Normal saline solution can maintain patency of arterial catheters and central venous pressure monitoring catheters. OBJECTIVES The current study aimed to compare th...
متن کاملFlushing and Locking of Venous Catheters: Available Evidence and Evidence Deficit
Flushing and locking of intravenous catheters are thought to be essential in the prevention of occlusion. The clinical sign of an occlusion is catheter malfunction and flushing is strongly recommended to ensure a well-functioning catheter. Therefore fluid dynamics, flushing techniques, and sufficient flushing volumes are important matters in adequate flushing in all catheter types. If a cathete...
متن کامل