Evaluation of algorithms for calculating bioimpedance phase angle values from measured whole-body impedance modulus.

نویسندگان

  • Bernt J Nordbotten
  • Christian Tronstad
  • Ørjan G Martinsen
  • Sverre Grimnes
چکیده

This paper addresses the problem of calculating the bioimpedance phase angle from measurements of impedance modulus. A complete impedance measurement was performed on altogether 20 healthy persons using a Solatron 1260/1294 system. The obtained impedance modulus (absolute impedance value) values were used to calculate the Cole parameters and from them the phase angles. In addition, the phase angles were also calculated using a Kramers-Kronig approach. A correlation analysis for all subjects at each frequency (5, 50, 100 and 200 kHz) for both methods gave R(2) values ranging from 0.7 to 0.96 for the Cole approach and from 0.83 to 0.96 for the Kramers-Kronig approach; thus, both methods gave good results compared with the complete measurement results. From further statistical significance testing of the absolute value of the difference between measured and calculated phase angles, it was found that the Cole equation method gave significantly better agreement for the 50 and 100 kHz frequencies. In addition, the Cole equation method gives the four Cole parameters (R(0), R(∞), τ(z) and α) using measurements at frequencies up to 200 kHz while the Kramers-Kronig method used frequencies up to 500 kHz to reduce the effect of truncation on the calculated results. Both methods gave results that can be used for further bioimpedance calculations, thus improving the application potential of bioimpedance measurement results obtained using relatively inexpensive and portable measurement equipment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cole Parameter Estimation from the Modulus of the Electrical Bioimpeadance for Assessment of Body Composition. A Full Spectroscopy Approach

Activities around applications of Electrical Bioimpedance Spectroscopy (EBIS) have proliferated in the past decade significantly. Most of these activities have been focused in the analysis of the EBIS measurements, which eventually might enable novel applications. In Body Composition Assessment (BCA), the most common analysis approach currently used in EBIS is based on the Cole function, which ...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

Bioimpedance Assessment of Oral Squamous Cell Carcinoma with Clinicopathological Correlation.

AIM Molecular alterations at membrane, cytosol and nuclear level in cancer cells/tissue show variations in bioimpedance measure. In the present study, bioimpedance assessment and comparison was investigated between oral squamous cell carcinoma (OSCC) and normal tissue. Study further involves clinicopathological correlation of bioimpedance values in OSCC. MATERIALS AND METHODS The present stud...

متن کامل

A Comparison between Impedance Measured by a Commercial Analyzer and Your Value Adjusted by a Theoretical Model in Body Composition Evaluation

The use of the electrical current on the evaluation of several physiological variables in the human body is not a recent technique but continues awaken a great interest in the research community. One of the greatest applications for such technique is the study of body composition through bioimpedance, where generally a equipment with tetrapolar array set of electrodes is used to realize the bio...

متن کامل

Effect of Influenza-Induced Fever on Human Bioimpedance Values

BACKGROUND AND AIMS Bioelectrical impedance analysis (BIA) is a widely used technique to assess body composition and nutritional status. While bioelectrical values are affected by diverse variables, there has been little research on validation of BIA in acute illness, especially to understand prognostic significance. Here we report the use of BIA in acute febrile states induced by influenza. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 32 7  شماره 

صفحات  -

تاریخ انتشار 2011