WE-G-213CD-05: Beam's-Eye-View Prostate Motion Detection during Arc Radiotherapy.
نویسندگان
چکیده
PURPOSE To track prostate motion during clinical arc radiotherapy using a novel statistical motion tracking algorithm in both phantom and patient systems. METHODS For the phantom study, a dynamic phantom with a custom tumor model and radiopaque fiducials was used. For the patient study, the clinical data from two prostate patients were acquired during volumetric modulated arc therapy (VMAT). For each patient, two gold fiducials (X-Mark, 1cm and 2cm in length) were implanted in the prostate. A total of 35 fractions with 2-field full arcs were delivered. Beam's-eye- view (BEV) images were acquired in cine mode every five fractions at a frame rate of 2 fps.The prostate motion was measured by two sequential steps: fiducial detection and motion estimation. In the first step, a wavelet- based block matching filter was used to suppress the noise and enhance the fiducials in the BEV images. A trajectory of detected fiducials was generated along the projection angles. Sequentially, the prostate motion was tracked using a statistical maximum a posteriori (MAP) algorithm. The 3-D fiducial position was estimated by maximizing the probability of displacement of 2-D projections. RESULTS A total of 8,400 BEV images were processed for this study. The phantom experiments showed that the baseline accuracy of estimation is 0.69+/-0.56 mm. For patient 1, intra- fraction prostate motion was measured to be 0.98+/-0.51 mm for all fractions, and individual fraction motion less than 1 mm. For patient 2, intra- fraction motion was 1.12+/-0.65 mm for all fractions. However, an exceptionally large displacement was measured as 4.9+/-0.74mm in one of the fractions. CONCLUSIONS Prostate motion during arc-therapy can be rigorously tracked to an accuracy of one millimeter. This technique is well suited for in-treatment room target tracking and post-therapy evaluation. Varian Medical Systems Inc.
منابع مشابه
Development of system using beam's eye view images to measure respiratory motion tracking errors in image‐guided robotic radiosurgery system
The accuracy of the CyberKnife Synchrony Respiratory Tracking System (SRTS) is considered to be patient-dependent because the SRTS relies on an individual correlation between the internal tumor position (ITP) and the external marker position (EMP), as well as a prediction method to compensate for the delay incurred to adjust the position of the linear accelerator (linac). We aimed to develop a ...
متن کاملReal‐time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement
BACKGROUND Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a prelim...
متن کاملIMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye view.
A new modification of the dynamic multileaf collimator (dMLC) delivery technique for intensity-modulated therapy (IMRT) is outlined. This technique enables the tracking of a target moving through rigid-body translations in a 2D trajectory in the beam's eye view. The accuracy of the delivery versus that of deliveries with no tracking and of 1D tracking techniques is quantified with clinically de...
متن کاملComputed tomography localization of radiation treatment delivery versus conventional localization with bony landmarks
A computed tomography (CT) scanner was installed in the linear accelerator room (Primatom) at Morristown. Since June 2000, we have been providing prostate, lung, and liver cancer patients with fusion of CT and linac radiation treatment. This paper describes our registration methods between planning and treatment CT images, and compares treatment localization by CT versus conventional localizati...
متن کاملForward‐planning intensity‐modulated radiotherapy technique for prostate cancer
In this study, we present an intensity-modulated radiotherapy technique based on forward planning dose calculations to provide a concave dose distribution to the prostate and seminal vesicles by means of modified dynamic arc therapy (M-DAT). Dynamic arcs (350 degrees) conforming to the beam's eye view of the prostate and seminal vesicles while shielding the rectum, combined with two lateral obl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part28 شماره
صفحات -
تاریخ انتشار 2012