Re: "Aneurysm sac pressure monitoring: effect of pulsatile motion of the pressure sensor on the interpretation of measurements".

نویسنده

  • Arindam Chaudhuri
چکیده

PURPOSE To determine the effect of pulsatile motion of graft-attached pressure sensors on the accuracy of aneurysm sac pressure measurement. METHODS Pressure inside a pressure box was measured with a sensor attached to a stent-graft (Sensorgraft) facing a sensor in fixed position (Sensorbox). Maximum inter-sensor variation of Sensorgraft and Sensorbox was determined in static experiments. Experiments with pulsatile circulation were performed with a compliant and a noncompliant stent-graft at 120/80 mmHg and 160/95 mmHg. Pressure measurements in the box were repeated after the box pressure was increased from 0 to 120 mmHg. Sensorgraft motion was measured by ultrasound. Measurements with Sensorgraft were compared to those with Sensorbox using Pearson correlation coefficients to determine the concordance between the sensors. RESULTS The maximum inter-sensor variation was 4 mmHg. Increased box pressure induced progressive pulsatile graft and sensor motion during all experiments. During the experiments with the compliant graft at systemic pressures of 120/80 and 160/95 mmHg, the maximum inter-sensor variation was exceeded at box pressures of 65 and 75 mmHg, respectively. The sensor motion at these box pressures was 214+/-2.70 microm and 210+/-0.93 microm, respectively. Measurements of Sensorgraft were higher than Sensorbox, up to 13 mmHg at a box pressure of 120 mmHg. The Pearson correlation coefficients during these experiments were 0.99 and 1.00 (p < 0.001), respectively. In the experiments with the noncompliant graft, the maximum inter-sensor variation was not exceeded, and sensor motion was only 7 +/- 0.46 microm and 26 +/- 1.48 microm, respectively. The Pearson correlation coefficient during these experiments was 1.00 (p < 0.001). CONCLUSION Pulsatile sensor motion can influence the accuracy of pressure measurement. More compliant grafts are more susceptible to this phenomenon. Despite false high pressure measurements, stent-graft-attached pressure sensors seem appropriate to follow pressure trends in the aneurysm sac.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of intraluminal thrombus on pressure transmission in the abdominal aortic aneurysm.

OBJECTIVE To clarify the effect of intraluminal thrombus on pressure transmission. METHODS A saccular aneurysm was inserted into an artificial circulation system. Subsequently, the saccular aneurysm was filled with eight different human aortic aneurysm thrombus samples. Starch solution in an empty aneurysm was used as a control. A pressure sensor measured the pressure in the circulation, and ...

متن کامل

Design of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane

This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...

متن کامل

Aneurysm sac pressure monitoring: effect of technique on interpretation of measurements.

OBJECTIVES The purpose of this study is to determine the accuracy of measuring pressure with a fluid filled pressure device (needle) and a non-fluid filled pressure device (catheter) inside a thrombosed aneurysmal sac after exclusion from circulation by endovascular grafting. METHODS In a static environment, consisting of a syringe to which a pressure monitoring kit was connected, experiments...

متن کامل

PULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW

Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...

متن کامل

Correlation Between Intrasac Pressure Measurements of a Pressure Sensor and an Angiographic Catheter During Endovascular Repair of Abdominal Aortic Aneurysm

PURPOSE To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSure wireless pressure sensor implant between March 19 and December 11, 2004 were enrolle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 2006