Lung function response to bronchodilator nebulization via hood in wheezy infants: a pilot study.

نویسندگان

  • Ephraim Bar-Yishay
  • Avraham Avital
  • Chaim Springer
  • Israel Amirav
چکیده

BACKGROUND In infants, small volume nebulizers with a face mask are commonly used to facilitate aerosol therapy. However, infants may be disturbed by mask application, causing poor mask-to-face seal and thus reducing the dose delivered. OBJECTIVES To compare lung function response to bronchodilator nebulization via two delivery devices: hood versus mask. METHODS We studied 26 recurrently wheezy infants aged 45.8 weeks (95% confidence interval 39.6-52.0). Inhalations of 0.30 mg/kg salbutamol were administered in two alliqots 30 minutes apart using mask and hood in alternating order (M+H or H+M). Response to inhalations was measured by maximal expiratory flows at functional residual capacity (V'maxFRC) at 5 minute intervals after each dose, and area under the V'maxFRC curve (AUC) was documented. RESULTS A small but significant response to salbutamol was observed following the second inhalation with V'maxFRC, improving by 31.7% (7.2-56.2, P (0.02) and AUC by 425% x min (-154, 1004; P < 0.02). The improvement following salbutamol was similar by both delivery modalities but with a small but significantly better response when H was used after M (P < 0.01). CONCLUSIONS Nebulized salbutamol induced a variable but positive response in wheezy infants. Salbutamol via hood was as effective as conventional face mask delivery. Since it is simple and patient-friendly, it could replace the face mask method particularly with uncooperative infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nebuliser hood compared to mask in wheezy infants: aerosol therapy without tears!

BACKGROUND Small volume nebulisers (SVNs) with masks commonly provide aerosol therapy for infants with lung diseases. However, infants and toddlers are often disturbed by and thus reject masks. AIMS To compare the lung deposition efficiency of the "usual" SVN aerosol mask and a prototype hood attached to an SVN. The advantage of the hood is that no mask is needed and medication can readily be...

متن کامل

Paradoxical response to nebulised salbutamol in wheezy infants, assessed by partial expiratory flow-volume curves.

Lower airway responses to nebulised bronchodilators were studied in 18 chronically or recurrently wheezy infants, aged 3-15 months, by means of partial forced expiratory flow-volume manoeuvres performed with an inflatable jacket. Maximum flow at functional residual capacity (FRC) (VmaxFRC) was used as the index of intrathoracic airways function. Peak expiratory flow rate was also measured. Base...

متن کامل

Delivery of salbutamol by metered dose inhaler and valved spacer to wheezy infants: effect on bronchial responsiveness.

The efficacy of a new valved spacer device, the Babyhaler inhaler (Glaxo) for administering metered dose inhaler treatment via a facemask to infants was assessed. In a double blind, single dose study, salbutamol (800 micrograms) or placebo were given on separate days to 12 sedated, sleeping, wheezy infants during a symptom free interval. Lung function was measured before and after administratio...

متن کامل

Inhaled salbutamol for wheezy infants: a randomised controlled trial.

BACKGROUND Salbutamol is frequently used as a bronchodilator for infants who wheeze. Many single dose studies have questioned its effectiveness. AIMS To investigate the response of wheezy infants to salbutamol over an extended time period in order to elucidate either symptomatic relief or a protective effect. METHODS Eighty infants under 1 year, with persistent or recurrent wheeze and a per...

متن کامل

Hypoxaemia in wheezy infants after bronchodilator

The response of the bronchi to nebulised salbutamol was measured in five recurrently wheezy infants. Changes in oxygenation (measured by pulse oximeter and transcutaneous P02 electrodes) and carbon dioxide (measured by transcutaneous PCO2 electrode) were recorded at the same time. Neither nebulised saline nor salbutamol caused any changes in the measurements of airway function. A significant dr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Israel Medical Association journal : IMAJ

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 2011