Images in cardiovascular medicine. Hiccups and dysphonic metallic voice: a unique presentation of Twiddler syndrome.

نویسندگان

  • Maurizio Gasparini
  • François Regoli
  • Carlo Ceriotti
  • Elisa Gardini
چکیده

Twiddler syndrome refers to a rare complication observed in patients with implanted pacemakers or defibrillators that causes device malfunction. The condition arises as a result of the patient’s conscious or unconscious manipulation of the device, causing its rotation in the pocket, resulting in torsion and dislodgment of the implanted lead(s). A 65-year-old obese woman with idiopathic dilated cardiomyopathy and diabetes mellitus had undergone implantation of a biventricular implantable cardioverter-defibrillator (CRT-D, Medtronic Insync Maximo 7304) with the positioning of 3 leads: a passive bipolar lead in the auricula of the right atrium (Medtronic Capsure Z Novus 5554), a bipolar, single-coil, screw-in lead (Medtronic Sprint 6931) in the apex of the right ventricle (RV), and a unipolar left-ventricular (LV) pacing lead (Medtronic Attain 4193) in an anterolateral tributary of the coronary sinus. Approximately 1 month after implantation, the patient presented to the emergency room with effort dyspnea followed by gradually worsening hiccups associated with dysphonia (a metallic or “pseudo-robot” voice was observed). The device was investigated: During threshold testing of the RV, no effective capture could be observed, even at maximum output. In contrast, when testing the unipolar LV lead (which in this model closes off on the RV coil), the symptoms of hiccups and “pseudo-robot” voice were immediately reproduced. The device was reprogrammed in VVI mode 30 bpm so that underlying spontaneous sinus rhythm emerged, and symptoms ceased immediately. Chest radiography (Figure 1) showed a macrodislodgment of the screw-in RV coil lead into the brachiocephalic vein (at the level of the esophagus) and an impressive cluster of catheter tangles in the subcutaneous pocket. The right atrium lead, although slightly retracted and with a large loop, appeared to have the tip in the correct position, with good sensing and pacing values. The LV unipolar lead (with the dipole closing on the RV coil in the brachiocephalic vein) initially presented a slight retraction but with good sensing and pacing threshold. Four days later, the patient underwent a revision procedure aiming at repositioning both the LV and RV coil leads. The chest radiograph at that point (Figure 2) revealed further retraction of both the RV and LV leads (no LV pacing was possible at that point). After incision into the skin and gentle extraction of the device, an impressive cluster of twisted catheter tangles connected to the device (Figure 3) was found. The device had rotated innumerous times on its central axis. As a consequence of the numerous loops and twists, both the RV lead coil and the LV lead had been deformed and needed replacement. Twiddler syndrome is a rare and potentially dangerous cause of lead dislodgment in patients with pacemakers and implantable cardioverter-defibrillators.1–4 The peculiar clinical presentations of Twiddler syndrome in conventional pacemakers include abdominal pulsation2 and stimulation of the pectoral major muscle.3 Patients who are most at risk for this condition include middle-aged obese women4 and patients with mental disorders such as dementia.5 To our knowledge, this is the first report of Twiddler syndrome in a CRT-D device with retraction of a screw-in defibrillation lead. The unique symptoms of hiccups and dysphonic metallic voice have never been reported before and were the result of the particular technical characteristics of the Medtronic CRT-D device system, in which the unipolar tip of the LV lead uses the RV defibrillator coil as the anode. The macrodislodgment of the RV coil (retracted into the brachiocephalic vein, at the level of esophagus) with consequent anatomic proximity to both recurrent and phrenic nerves caused an electrical irritation of these nerves, hence explaining the very odd symptoms. Treatment measures to avoid or limit Twiddler syndrome in patients at increased risk include limiting the pocket size and the suturing of the device to the fascia.6

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

The First Presentation of Pediatric COVID-19 With Diabetic Ketoacidosis: A Unique Case Report

Introduction: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), or COVID-19, is a pandemic infectious disease involved all over the world. Its mortality, especially in cases with additional co-morbidities, is so high that is has attracted the attention of the world. Diabetes mellitus is known as one of its risk factors for mortality. Case Presentation:...

متن کامل

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

Persistent hiccups as an atypical presentation of covid-19: a brief report

Background: coronavirus disease (COVID-19) as an emerging infectious disease started in China in 2019. By increasing the number of patients and spreading to all countries, it was considered a pandemic disease. COVID-19 became an international concern. Patients affected by coronavirus (SARS-Cov-2) reported different symptoms. Most signs and symptoms were related to the respiratory system. To our...

متن کامل

Novel Presentation of Complete Coronal Urethral Duplication: a Case Report

     Urethralduplication is a rare condition occurs as a congenital malformation either independently or in the setting of other congenital malformations such as caudal duplication syndrome. Its prevalence becomes even rarer if it manifests as two side-by-side tracts in coronal plan.Nonetheless, we introduce a unique presentation of complete coronal urethral duplication accompanied by astoundin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 114 15  شماره 

صفحات  -

تاریخ انتشار 2006