Rating Technique for Refrigeration Twin-Screw Compressors

نویسنده

  • Lars Sjoholm
چکیده

The twin-screw compressor is constantly attaJ.ninq hiqher performance due to new rotor profiles, new rotor manufacturing technology and new designs. Besides this, new refrigerants as well as new lubricants can be expected on the market. Therefore there is always a need to update performance data. To m1nimize the number of test points and still receive representative data, there 1s a need of an accurate and compact rating equation system. Certa1n relationships have become clear for representation of volumetric efficiency and power consumption as a result of analysing the behaviour of the tw1n-screw compressor. The relationships include fixed and variable volume ratio, as well as econom1zer operation. Baslc rating equations are described and comparisons between rating equation data and test data are made. INTRODUCTION The curve fitting technique described in tllis paper is mainly developed for the oil-flooded twin-screw refrigeration compressor (ref. 1). The twin-screw compressor is a positive displacement compressor with a built-in volume ratio, no suction or discharge valves, no clearance volume, but with a certain amount of internal leakage. This fact makes it to behave differently from other positive displacement compressors, like the rec1procating compressor. Rating technique for reciprocating compresson is described in reference 2. The performance rating data has to be based on test data and/or performance simulation data (ref. 3, 4, 5). Such performance simulation programs should be used for analysing the compressor itself and they are normally too complicated and the executing time is too long for refrigeration system analysis. The rating equations described in this paper are more suited for refrigeration system design, and analysis, centered around the twin -screw compressor. CAPACITY CALCULATIONS The refrigeration capacity Q (kW) .1s: Q ; NVOL VS NM DH X X WX V where NVOL vs NM v DH volumetric efficency, theoretical compressor displacement (m3/rev), input male rotor speed (rpm), specific volume at suction (m3/kg), enthalpy difference over the evaporator (kJ/kg). (1) Seeing this equation it is natural to curve fit the volumetric efficiency instead of the refrigeration capacity. The volumetric efficiency is normally a straight line when plotted against pressure ratio (for constant discharge pressure). The volumetric efficiency drops when the pressure ratio is increased and the drop is magnified by: low buil t-.in volume ratio, low rotor speed, low viscosity of lubricant-refrigerant mixture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

The design of two series of twin screw compressors for being used in refrigeration applications are reported in this paper. The capacity range for the open type series is from 85 to 4300 h m / 3 , and for the semi-hermetic series from 120 to 2600 h m / 3 . The rotor profile and other design parameters are optimized with the help of the software package SCCAD. Many new features are adopted in th...

متن کامل

Noise Source Identification in Semi-Hermetic Twin-Screw Compressors

The sound radiation characteristics of a semi-hermetic twin-screw compressor were studied while operating under controlled laboratory conditions at the Ray W. Herrick Laboratories of Purdue University. A fully-condensing load stand was designed to allow the 70 ton chiller system to be operated at the three standard loading capacities of the compressor. The load stand was operator controlled and...

متن کامل

Optimisation Techniques Applied to the Design of a Refrigeration TiN Screw Compressor

Some results from a procedure for optimising the geometrical parameters of a refrigeration twin screw compressor, such as the basic geometrical parameters of its profile and the position of its discharge port etc., were presented by the authors at the International Compressor Engineering Conference at Purdue, 1992. In this paper the optimisation technique is developed by making use of programs ...

متن کامل

Important Parameters for Small, Twin-Screw Refrigeration Compressors

This paper deals with open-shaft twin-screw refrigeration compressors in the 10 175 m3/h (10 100 CFM) range. Applications for such compressors are, for example,external combustion engine heat-pumps and transport refrigeration. The twin-screw compressor concept is discussed from following view-points; operational mode and rotor housing design drive arrangement bearings lubricants cooling volume ...

متن کامل

Optimum Rotor Geometrical Parameters in Refrigeration Helical Twin Screw Compressors

This paper presents a parameter study for optimum rotor geometrical parameter combinations of a refrigeration helical twin screw compressor with four commonly used lobe combinations and five different length/diameter ratios and wrap angles. The volumetric and indicated efficiencies of the compressor are important. So also are other factors such as rotor deflection, bearing load, bearing life an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014