A maximum likelihood proton path formalism for application in proton computed tomography.
نویسندگان
چکیده
The limited spatial resolution in proton computed tomography (pCT) in comparison to x-ray CT is related to multiple Coulomb scattering (MCS) within the imaged object. The current generation pCT design utilizes silicon detectors that measure the position and direction of individual protons prior to and post-traversing the patient to maximize the knowledge of the path of the proton within the imaged object. For efficient reconstruction with the proposed pCT system, one needs to develop compact and flexible mathematical formalisms that model the effects of MCS as the proton traverses the imaged object. In this article, a compact, matrix-based most likely path (MLP) formalism is presented employing Bayesian statistics and a Gaussian approximation of MCS. Using GEANT4 simulations in a homogeneous 20 cm water cube, the MLP expression was found to be able to predict the Monte Carlo tracks of 200 MeV protons to within 0.6 mm on average when employing 3sigma cuts on the relative exit angle and exit energy. These cuts were found to eliminate the majority of events not conforming to the Gaussian model of MCS used in the MLP derivation. M riszwana Banu
منابع مشابه
Block-Iterative and String-Averaging Projection Algorithms in Proton Computed Tomography Image Reconstruction
Proton computed tomography (pCT) is an imaging modality that is based on tracking individual protons as they traverse the object to be imaged. Proton-by-proton tracking is necessary due to the effects of multiple Coulomb scattering (MCS), a process that deviates the proton path from a striaght line. If optimal spatial resolution is to be achieved, the path of each proton must be predicted with ...
متن کاملNONDYNAMICAL ANALYSIS OF SPIN AMPLITUDES IN PION-PROTON ELASTIC SCATTERING IN OPTIMAL FORMALISM AT 6.0 GeV/C
Optimal conditions are used in nondynamical formalism to diagonalize the pionproton reaction matrix as much as possible. Invariance laws are imposed to simplify the relationship between observables and bilinear combination of amplitudes. Transverse amplitudes are determined by using measured polarization parameter in xfp elastic scattering at 6.0 GeVIC
متن کاملEvaluation of the effective dose during PBFT for brain cancer: A Monte Carlo Study
Introduction: Recently, an approach exploiting the proton therapy biological enhancement by using Boron atoms injected inside a tumor, has been proposed. Three alpha particles with an average energy around 4MeV are emitted from the point of reaction between a proton and boron. In addition, the 719 keV prompt gamma emitted by the proton Boron fusion reactions can be used for on-...
متن کاملStudying dose equivalents of radio-sensitive organs in head and neck region during nasopharynx proton therapy using Monte Carlo MCNPX code
In the present work, dose equivalents of radiosensitive organs in head and neck region have been calculated during nasopharynx proton therapy. For this purpose, a middle-size tumor was designed with the use of clinical information, and was then incorporated into the adult male ICRP phantom. According to the medical data, eight radiation paths around the neck were selected. After that, appropria...
متن کاملReconstruction for proton computed tomography by tracing proton trajectories: a Monte Carlo study.
Proton computed tomography (pCT) has been explored in the past decades because of its unique imaging characteristics, low radiation dose, and its possible use for treatment planning and on-line target localization in proton therapy. However, reconstruction of pCT images is challenging because the proton path within the object to be imaged is statistically affected by multiple Coulomb scattering...