Development of RadRob15, A Robot for Detecting Radioactive Contamination in Nuclear Medicine Departments
نویسندگان
چکیده
Accidental or intentional release of radioactive materials into the living or working environment may cause radioactive contamination. In nuclear medicine departments, radioactive contamination is usually due to radionuclides which emit high energy gamma photons and particles. These radionuclides have a broad range of energies and penetration capabilities. Rapid detection of radioactive contamination is very important for efficient removing of the contamination without spreading the radionuclides. A quick scan of the contaminated area helps health physicists locate the contaminated area and assess the level of activity. Studies performed in IR Iran shows that in some nuclear medicine departments, areas with relatively high levels of activity can be found. The highest contamination level was detected in corridors which are usually used by patients. To monitor radioactive contamination in nuclear medicine departments, RadRob15, a contamination detecting robot was developed in the Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC). The motor vehicle scanner and the gas radiation detector are the main components of this robot. The detection limit of this robot has enabled it to detect low levels of radioactive contamination. Our preliminary tests show that RadRob15 can be easily used in nuclear medicine departments as a device for quick surveys which identifies the presence or absence of radioactive contamination.
منابع مشابه
Development of RadRob15, A Robot for Detecting Radioactive Contamination in Nuclear Medicine Departments
Accidental or intentional release of radioactive materials into the living or working environment may cause radioactive contamination. In nuclear medicine departments, radioactive contamination is usually due to radionuclides which emit high energy gamma photons and particles. These radionuclides have a broad range of energies and penetration capabilities. Rapid detection of radioactive contami...
متن کاملFeasibility of detecting and localizing radioactive source using image processing and computational geometry algorithms
We consider the problem of finding the localization of radioactive source by using data from a digital camera. In other words, the camera could help us to detect the direction of radioactive rays radiation. Therefore, the outcome could be used to command a robot to move toward the true direction to achieve the source. The process of camera data is performed by using image processing and computa...
متن کاملContamination monitoring of Na¹³¹I levels in therapy unit of Research Institute for Nuclear Medicine, Tehran University of Medical Sciences by indirect method (Wipe test) [Persian]
Contamination with radiopharmaceuticals in nuclear medicine centers in addition to being a health concern requires time-consuming decontamination efforts. According to NRC (Nuclear Regulatory Commission) contamination should be monitored in nuclear medicine centers where radiopharmaceuticals are prepared and administrated at the end of each working session; otherwise, contamination spread...
متن کاملUsing starch powder for the decontamination of I-131 in isolation rooms
Introduction: Various iodine isotopes are undergoing radioactive decay except Iodine-127 (I-127. Iodine I-131 is unsealed radioactive material used in nuclear medicine for both diagnostic and therapeutic procedures in Royal Hospital since 2006. In radiotoxic classification, I-131 is in group 2 element. I-131 is highly reactive element due to its volatilization nature. Currently...
متن کاملبررسی میزان آلودگی های رادیواکتیو در مراکز پزشکی هسته ای استان همدان به روش Wipe Test
Introduction: Possible contamination in nuclear medicine centers, in addition to health problems, affect the tests and much effort and cost is required for decontamination. Given the effects of ionizing radiation on human health, rules and regulations have been enacted to avoid contamination, that in working with radioactive materials should be followed to minimize them. . Material and Method:...
متن کامل