Percutaneous hemodynamic support with Impella 2.5 during scar-related ventricular tachycardia ablation (PERMIT 1).

نویسندگان

  • Marc A Miller
  • Srinivas R Dukkipati
  • Jason S Chinitz
  • Jacob S Koruth
  • Alexander J Mittnacht
  • Craig Napolitano
  • Andre d'Avila
  • Vivek Y Reddy
چکیده

BACKGROUND Percutaneous left ventricular assist devices (pLVADs) are increasingly being used to facilitate ablation of unstable ventricular tachycardia (VT), but the safety profile and hemodynamic benefits of these devices have not been described in a systematic, prospective manner. METHODS AND RESULTS Twenty patients with scar VT underwent ablation with a pLVAD. Neuromonitoring using cerebral oximetry was performed to evaluate a cerebral desaturation threshold to guide the duration of activation/entrainment mapping. The efficacy of pLVAD support was tested in a controlled manner with simulated VT. Complete procedural success was achieved in 50% (n=8) of patients, who were initially inducible for sustained VT, and partial procedural success in 37% (n=6). Using a cerebral desaturation level of 55% as a lower safety limit to guide the duration of sustained VT, 3 patients (15%) developed mild acute kidney injury (all resolved), and 1 (5%) patient developed mild cognitive dysfunction. During fast simulated VT (300 ms), cerebral desaturation to ≤55% occurred in more than half (53%) of patients tested without pLVAD support, compared with only 5% with full pLVAD support (P=0.003). CONCLUSIONS In a consecutive series of patients with severe left ventricular dysfunction, pLVAD-supported scar VT ablation was safe and feasible. During fast simulated VT, a miniaturized axial flow pump imparted a more favorable hemodynamic profile compared with pharmacological agents alone. Cerebral oximetry is a complimentary monitoring modality during scar VT ablation, and avoidance of cerebral desaturations below a threshold of 55% may safely guide the duration of mapping during unstable VT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: the PROTECT II study.

BACKGROUND Although coronary artery bypass grafting is generally preferred in symptomatic patients with severe, complex multivessel, or left main disease, some patients present with clinical features that make coronary artery bypass grafting clinically unattractive. Percutaneous coronary intervention with hemodynamic support may be feasible for these patients. Currently, there is no systematic ...

متن کامل

Percutaneous left ventricular assist devices in ventricular tachycardia ablation: multicenter experience.

BACKGROUND Data on relative safety, efficacy, and role of different percutaneous left ventricular assist devices for hemodynamic support during the ventricular tachycardia (VT) ablation procedure are limited. METHODS AND RESULTS We performed a multicenter, observational study from a prospective registry including all consecutive patients (N=66) undergoing VT ablation with a percutaneous left ...

متن کامل

Outcomes of Ventricular Tachycardia Ablation Using Percutaneous Left Ventricular Assist Devices.

BACKGROUND Although percutaneous left ventricular assist devices (pLVADs) facilitate mapping and ablation of hemodynamically unstable ventricular tachycardia (VT), there is limited data whether clinical outcomes are improved. We sought to retrospectively compare the outcomes of patients undergoing scar-related VT ablation with and without pLVAD support. METHODS AND RESULTS The study populatio...

متن کامل

A prospective feasibility trial investigating the use of the Impella 2.5 system in patients undergoing high-risk percutaneous coronary intervention (The PROTECT I Trial): initial U.S. experience.

OBJECTIVES We sought to evaluate the safety and feasibility of the Impella 2.5 system (Abiomed Inc., Danvers, Massachusetts) in patients undergoing high-risk percutaneous coronary intervention (PCI). BACKGROUND The Impella 2.5 is a miniaturized percutaneous cardiac assist device, which provides up to 2.5 l/min forward flow from the left ventricle into the systemic circulation. METHODS In a ...

متن کامل

Activation and entrainment mapping of hemodynamically unstable ventricular tachycardia using a percutaneous left ventricular assist device.

OBJECTIVES Our goal was to investigate the effects of percutaneous left ventricular assist device (pLVAD) support during catheter ablation of unstable ventricular tachycardia (VT). BACKGROUND Mechanical cardiac support during ablation of unstable VT is being increasingly used, but there is little available information on the potential hemodynamic benefits. METHODS Twenty-three consecutive p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2013