The Measurement Procedure
ثبت نشده
چکیده
This experiment* was designed to lay the foundations for a standard procedure for measuring the quality of scientific translations, whether human or mechanical. There have been other experiments on this problem [e.g., G. A. Miller and J. G. BeebeCenter, Mechan. Transl. , 3, 73 (1958); S. M. Pfafflin, Mechan. Transl. 8, 2 (1965)], but their methods for evaluating translations have been too laborious, too subject to arbitrariness in standards, or too lacking in reliability and/or validity to become generally accepted. The measurement procedure developed here gives promise of being amenable to refinement to the point where it will meet the requirements of relative simplicity and feasibility, fixed standards of evaluation, and high validity and reliability. A detailed report of this experiment will be submitted for publication elsewhere; the present brief report will serve to indicate the general nature of the measurement procedure and some of the chief results.
منابع مشابه
Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملResidual Stresses Measurement of a Quenched Cylinder using Slitting Method
Residual Stress measurement has gained interests among researchers for many years due to its great influence on the structural integrity. Slitting method is one of the destructive techniques that relies on the introduction of an increasing cut to a part containing residual stresses. Similar to all other mechanical strain relief techniques, slitting also suffers from its shortcomings during the ...
متن کاملComparative evaluation of alveolar bone level measurement pre and at gingival surgery
Comparative evaluation of alveolar bone level measurement pre and at gingival surgery Dr. R. Shariatmadar Ahmadi* - Dr. KH. Mani Kashani** - Dr. N. Dorri*** * - Assistant Professor of Periodontics Dept. Faculty of Dentistry – Hamedan University of Medical Sciences. **- Assistant Professor of MSPH Dept. – Faculty of Medicine – Hamedan University of Medical Sciences. *** - Dentist. Background and...
متن کاملInfrared Thermopile Temperature Measurement Technique in Microwave Heating Systems
Temperature measurement in microwave systems is essential for thermally driven processes, namely, catalytic reactions and ceramic sintering. Although, the application of direct thermometry methods, namely, thermocouples, have been commonly articulated in the available literature, however, contacted temperature measurement mechanisms have aroused concerns associated with the disruption of the el...
متن کاملNon-ionizing electromagnetic waves measurement and monitoring Systems
In this paper, portable and online monitoring systems for non-ionizing EMF measurement, as well as some measurement results in Tehran are discussed. First of all, standards and recommendations related to EMF monitoring, measurement and exposure such as ISIRI No.8567, ICNIRP guideline and ITU-K.83 are reviewed. Then, technical facts and operation of portable device and monitoring station are int...
متن کاملDetermination of the Lag Time or Susceptibility in LDL Oxidation Procedure
ABSTRACT Much researches has focused on the theory that antioxidant nutrients act as scavengers of oxygen derived free radicals, thereby helping to prevent cell and tissue damage that otherwise would give rise to degenerative diseases such as atherosclerosis caused by LDL oxidation. Findings from extensive studies suggested that the determination of lag objective procedure for determining the ...
متن کامل