Comparison between an automated and manual sphygmomanometer in a population survey.
نویسندگان
چکیده
BACKGROUND An automated sphygmomanometer, the BpTRU, was used in a blood pressure (BP) survey of 2,551 residents in the province of Ontario. Automated BP readings were compared with measurements taken by a mercury sphygmomanometer under standardized conditions in a random 10% sample. METHODS BP was recorded in 238 individuals in random order using both a standard mercury device and an automated BP recorder, the BpTRU. All subjects rested for 5 min prior to the first BP reading, which was then discarded. The mean of the next three readings was obtained using the mercury device whereas the BpTRU was set to record a mean of five readings taken at 1 min intervals with subjects resting alone in a quiet room. RESULTS The mean s.d. BP with the automated device was 115 +/- 16/71 +/- 10 mm Hg compared to 118 +/- 16/74 +/- 10 mm Hg for the manual BP (P < 0.001). A systolic BP > or = 140 mm Hg was present for 16 automated and 19 manual readings. Similarly, the diastolic BP was > or = 90 mm Hg for 9 automated and 14 manual readings. Linear regression analysis showed that automated BP was a significant (P < 0.001) predictor of both manual systolic and diastolic BP. CONCLUSION Conventional manual BP readings can be replaced by readings taken using a validated, automated BP recorder in population surveys. The slightly lower readings obtained with the BpTRU device (in the context of reduced observer-subject interaction) may be a more accurate estimate of BP status.
منابع مشابه
Automated sphygmomanometers should not replace manual ones, based on current evidence.
To the Editor: Myers et al.1 in their article “Comparison Between an Automated and Manual Sphygmomanometer in a Population Survey” compared blood pressures (BPs) measured with a standard mercury sphygmomanometer and an oscillometric sphygmomanometer and concluded that “conventional manual BP readings taken using mercury sphygmomanometry can be replaced by (readings taken using) a validated, aut...
متن کاملAutomated versus manual blood pressure measurement: a randomized crossover trial.
This study evaluated the accuracy and reliability of the Dinamap 8100 automated blood pressure machine against three internationally recognized criteria. Systolic and diastolic blood pressures were taken concurrently by two nurses using the automated machine and a manual sphygmomanometer. Results demonstrated agreement between automated and manual readings on one set of criteria for both systol...
متن کاملمقایسه شمارش خودکار با شمارش دستی نوتروفیلها در تشخیص پریتونیت باکتریال خود به خودی
Introduction: Spontaneous bacterial peritonitis (SBP) is a prevalent complication in the patients with cirrhosis and ascites, which leads to high intrahospital mortality. Diagnosis is made when ascetic fluid neutrophils is ≥250 cells/mm3. Manual counting of neutrophils is time-consuming, technically difficult, expensive and in many cases individual-dependent. In contrast, automated counting ...
متن کاملValidity of Selected WBC Differentiation Flags in Sysmex XT-1800i
Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC d...
متن کاملCARDIOVASCULAR DISEASES Difference in blood pressure readings with mercury and automated devices: impact on hypertension prevalence estimates in Dar es Salaam, Tanzania
Objectives: (1) To compare blood pressure (BP) readings with an automated arm cuff oscillometric device (AutoBP) to readings with a mercury sphygmomanometer (HgBP) and (2) to evaluate the impact on the prevalence of hypertension (HBP) in a population-based survey. Methods: (1) In a convenience sample (‘‘Comparison Study’’), we measured BP with both AutoBP (Visomat OZ2) and HgBP and we modeled B...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of hypertension
دوره 21 3 شماره
صفحات -
تاریخ انتشار 2008