Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode
نویسندگان
چکیده
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2South China Sea Institute of Oceanology, Chinese Academy of Sciences, Guangzhou 510301, P. R. China 3Graduate School of the Chinese Academy of Sciences, Beijing 100049, P. R. China
منابع مشابه
Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes
Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...
متن کاملApplication of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion
A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
متن کاملHigh-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
متن کاملApplication of a New Macrocyclic -PVC Electrode to Potentiometric Studies of Fe(III) Ion
A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....
متن کامل