Multicenter Comparison of 3D Spinal Measurements Using Surface Topography With Those From Conventional Radiography.

نویسندگان

  • Patrick Knott
  • Peter Sturm
  • Baron Lonner
  • Patrick Cahill
  • Marcel Betsch
  • Richard McCarthy
  • Michael Kelly
  • Lawrence Lenke
  • Randal Betz
چکیده

INTRODUCTION In pediatric spinal deformity the gold standard for curve surveillance remains standing full-column radiographs, but repeated exposure to ionizing radiation motivates us to look for nonradiographic solutions. This study tests a modern system of surface topography (ST) to determine whether it is reliable and reproducible. METHODS Patients from 6 pediatric spinal deformity clinics were recruited for enrollment. Inclusion criteria were age 8-18; diagnosis of scoliosis measuring ≥10 and <50 degrees or increased kyphosis of ≥45 degrees. Standing radiographs and ST scans (DIERS Formetric, Diers Medical Systems, Chicago, IL) were obtained on all patients and then measured and compared. A single investigator using a validated electronic measurement tool performed all radiographic measurements. Analysis of reproducibility and comparison of ST and radiographs were done. RESULTS A total of 193 patients were enrolled (148 F [77%]). The mean age was 13.25 years (range 8-18). The scoliosis magnitude was as follows: thoracic average 22.7 ± 10 degrees; lumbar average 19.6 ± 9 degrees. The kyphosis magnitude was 54.0 ± 11 degrees. The reproducibility for each ST parameter for 3 repeated scans was strong (interclass correlation = 0.855-0.944). Comparison to radiographic measurements was strong in the thoracic (r = 0.7) and moderate in the lumbar curve (r = 0.5). There was an average difference of 5.8 degrees in the thoracic spine and 8.8 degrees in the lumbar spine between ST Cobb angle estimates and radiographs. Thoracic kyphosis also had a strong correlation (r = 0.8) with radiographs. CONCLUSIONS Although the results are intended to measure similar aspects of deformity as the traditional Cobb angle, the measurement is not intended to be an exact estimation. The utility of ST is in the reproducible quantification of deformity after the initial radiograph has been taken. This has the potential to make longitudinal assessment of change in deformity without serial radiographs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, implementation and first results of a 3RD generation digital photogrammetric system from trunk surface assessment and scoliosis screening

Background Scoliosis patients typically undergo numerous spinal radiographs and exposed to relatively high doses of ionizing radiation. This has raised concern regarding the effects of this repeated exposure. Additionally assessment of spinal deformities using surface topography of the back is currently considered essential. Digital Photogrammetry can contribute in non-invasive measurements of ...

متن کامل

Comparison of Radiographic and Surface Topography Measurements in Adolescents with Idiopathic Scoliosis

PURPOSE In patients with adolescent idiopathic scoliosis (AIS), radiographic surveillance is the gold standard of assessing spinal deformity, but has negative long-term effects. The Formetric 4D surface topography system was compared to standard radiography as a safer option for evaluating patients with AIS. METHODS Fourteen volunteers with typical AIS patient stature had 30 repeated Formetri...

متن کامل

Comparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography

Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...

متن کامل

The influence of body mass index (BMI) on the reproducibility of surface topography measurements

Background Surface Topography can be used to evaluate patients with spinal deformity, especially adolescents with scoliosis in whom a reduced number of radiographic evaluations is desired. The Formetric 4D (Diers International GmbH, Schlangenbad, Germany) is a surface topography system that is able to identify anatomical landmarks and construct a 3-dimentional model of the spine using only surf...

متن کامل

The comparison of dose distribution of different 3D conformal and conventional radiotherapy plans for gastric cancer

Aims: It was aimed to investigate postoperative conformal radiotherapy planning that provides the best target volume and the least dose for critical organs in cancers of stomach. Methods: This study was conducted on the CT simulation images of thirty patients diagnosed with gastric cancer. Target volumes and the organs at risk were contoured. AP-PA reciprocal parallel field conventional plan an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine deformity

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2016