Spectrophotometric Determination of Alfuzosin HCl in Pharmaceutical Formulations with some Sulphonephthalein Dyes

نویسندگان

  • Safwan Ashour
  • M. Fawaz Chehna
  • Roula Bayram
چکیده

Bromocresol purple (BCP), bromophenol blue (BPB) and bromothymol blue (BTB) were used to determine alfuzosin hydrochloride either in pure form or in pharmaceutical formulations. Alfuzosin was extracted as an ion-pair complex from sample solution containing KCl-HCl buffer pH2.2, 2.4 and 2.6 into CHCl3 and the absorbance was measured at 407, 413 and 412nm with use of the cited reagents, respectively. The analytical parameters and their effects on the reported systems are investigated. The reactions were extremely rapid at room temperature and the absorbance values remains unchanged up to 24 h. Beer's law was obeyed in the concentration ranges 1.20-38.3, 0.85-46.0 and 0.63-34.0 μg/ml and detection limits were 0.28, 0.24 and 0.18 μg/ml with BCP, BPB and BTB, respectively. Recoveries were 98.80-101.33%. Interferences of the other ingredients and excipients were not observed. The proposed method is simple, fast and sensitive, and the first reported extractive method for the determination of alfuzosin in commercial tablets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of new spectrophotometric methods for the determination of Alfuzosin hydrochloride in bulk and pharmaceutical formulations

Two simple and sensitive methods A and B for the spectrophotometric determination of Alfuzosin hydrochloride have been described. These methods are based on the formation of purple color and redviolet colored chromogens obtained when the drug was diazotized with nitrous acid followed by coupling with Phloroglucinol and Resorcinol, exhibiting λmax at 520 and 600 nm respectively. These methods ob...

متن کامل

Spectrophotometric determination of distigmine bromide, cyclopentolate HCl, diaveridine HCl and tetrahydrozoline HCl via charge transfer complex formation with TCNQ and TCNE reagents

The purpose of this investigation was directed to propose sensitive, accurate and reproducible methods of analysis that can be applied to determine distigmine bromide (DTB), cyclopentolate hydrochloride (CPHC), diaveridine hydrochloride (DVHC) and tetrahydrozoline hydrochloride (THHC) drugs in pure form and pharmaceutical preparations via charge-transfer complex formation with 7,7,8,8-tetracyan...

متن کامل

Spectrophotometric determination of distigmine bromide, cyclopentolate HCl, diaveridine HCl and tetrahydrozoline HCl via charge transfer complex formation with TCNQ and TCNE reagents

The purpose of this investigation was directed to propose sensitive, accurate and reproducible methods of analysis that can be applied to determine distigmine bromide (DTB), cyclopentolate hydrochloride (CPHC), diaveridine hydrochloride (DVHC) and tetrahydrozoline hydrochloride (THHC) drugs in pure form and pharmaceutical preparations via charge-transfer complex formation with 7,7,8,8-tetracyan...

متن کامل

Development and Validation of First Order Derivative Spectrophotometric Method for Estimation of Alfuzosin Hydrochloride and Finasteride in Combined Dosage Form

The present manuscript describe simple, sensitive, rapid, accurate, precise and economical first derivative spectrophotometric method for the simultaneous determination of alfuzosin hydrochloride and finasteride in combined tablet dosage form. The derivative spectrophotometric method was based on the determination of both the drugs at their respective zero crossing point (ZCP). The first order ...

متن کامل

Partial Least Square and Parallel Factor Analysis Methods Applied for Spectrophotometric Determination of Cefixime in Pharmaceutical Formulations and Biological Fluid

In this study, the direct determination of cefixime as an anti-bacterial agent, in pharmaceutical formulations, urine and human blood plasma was conducted based on spectrophotometric measurements using parallel factor analysis (PARAFAC) and partial least squares (PLS). The calibration set was composed of fourteen solutions in the range of 0.50- 9.00 µg mL-1. PLS models were calculated at each p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2006