Three-dimensional volume change of grafted bone in the maxillary sinus.

نویسندگان

  • Fabio Mazzocco
  • Diego Lops
  • Luca Gobbato
  • Alessandra Lolato
  • Eugenio Romeo
  • Massimo del Fabbro
چکیده

PURPOSE The purpose of this study was to evaluate the three-dimensional radiographic changes of 100% anorganic bovine bone xenograft volume in a grafted maxillary sinus, based on a computerized analysis of cone-beam computed tomography (CBCT) scan. MATERIALS AND METHODS A maxillary sinus augmentation procedure done with a lateral approach using 100% anorganic bovine bone was performed in 20 patients. A CBCT scan of the grafted area was taken immediately after the procedure (T1) and 8 to 9 months later (T2). CBCT scan data were analyzed with image processing software to evaluate differences in the volume of grafted material between T1 and T2. Residual ridge height and width were also measured at T1. RESULTS The mean residual bone height and width at the implant sites was 4.40±0.87 mm and 7.9±2.22 mm, respectively. The mean graft volume was 1,432±539 mm³ and 1,287±498 mm³ at T1 and T2, respectively. A significant difference in graft volume was found between T1 and T2 data by paired t test (P=.01). The mean ratio between the volume at T2 and the volume at T1 was 0.90±0.12, meaning a graft volume contraction of 10%. CONCLUSION Within the limits of the present investigation, good stability of anorganic bovine bone graft volume up to 8 months after the grafting procedure was demonstrated. Three-dimensional computed tomographic volumetric assessment seems to be a promising approach to quantify long-term changes in the regenerated area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Anatomical Variations of Sinonasal Area and Maxillary Sinus Pneumatization

Introduction: Maxillary sinuses are among the largest paranasal sinuses with various shapes and volumes. The dimensions and volumes of maxillary sinuses play an important role in the surgical treatment plan. The higher levels of pneumatization of alveolar bone lead to the increase of odontogenic sinusitis which cause problems in dental implantation. Therefore, this study aimed to evaluate...

متن کامل

Measurement of maxillary sinus volume using computerized tomographic images.

This study measured maxillary sinus volume as an aid in determining the volume of graft bone needed before grafting autogenous bone to the maxillary sinus floor. Maxillary sinus volumes were measured from computerized tomographic images of 38 sinuses using a 3-dimensional reconstruction system. When the sinus-lift procedure was simulated, volumes (mean +/- SD) of the inferior portion of the sin...

متن کامل

Three-Dimensional Assessment of Volumetric Changes in Sinuses Augmented with Two Different Bone Substitutes

Introduction. The bone volume of the posterior maxilla may not be appropriate for implant placement, due to factors such as pneumatized maxillary sinus. The purpose of this study was to evaluate the percentage of graft volume reduction following sinus floor elevation (SFE), with either slow resorbable bone substitute only or a composite of slow and fast resorbable bone substitutes, using cone b...

متن کامل

Assessment of the autogenous bone graft for sinus elevation

OBJECTIVES The posterior maxillary region often provides a limited bone volume for dental implants. Maxillary sinus elevation via inserting a bone graft through a window opened in the lateral sinus wall has become the most common surgical procedure for increasing the alveolar bone height in place of dental implants in the posterior maxillary region. The purpose of this article is to assess the ...

متن کامل

بررسی دقت توموگرافی خطی در تعیین محل حفره بینی و سینوس ماگزیلاری1

Background and Aim: Accurate measurement of bone height and width is essential prior to dental implant placement. The method of surgery as well as, the type and size of implants are determined according to dimensions of the residual bone. The purpose of this study was to evaluate the accuracy of linear tomography in localization of the floor of nasal fossa and maxillary sinus, and to determine ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2014