Development of Ultrafast Laser-based Micro-ct System for Small Animal Imaging

نویسندگان

  • A. Krol
  • J -C. Kieffer
  • R. Toth
  • E. D. Lipson
  • R. E. Kincaid
  • I. L. Coman
چکیده

We investigated performance of ultrafast (30 fs –200 fs) laser-based x-ray source as an alternative to a microfocal x-ray tube used in micro-CT systems. A number of solid targets including Ge, Mo, Rh, Ag, Sn, Ba, La, Nd with matching filters was used. We optimized conditions for x-rays generation, measured x-ray spectra and obtained images of small animals using various characteristic x-ray lines and various imaging geometries. X-ray spectra produced by ultrafast laser are advantageous for micro-CT imaging because most of the emission is in narrow characteristic lines. The spectra can be rapidly changed, via target change, and easily matched to the imaging task. X-ray fluence can exceed fluence produced by conventional microfocal tube. Effective x-ray focal spot size is about 5 μm. Good quality projection images of small animals were obtained: (a) in a single energy absorption mode with single x-ray line matching animal thickness and density, and (b) in the dual-energy absorption mode with two x-ray lines bracketing absorption energy of the I-based and Ba-based contrast agent, respectively, and (c) in the in line phase-contrast enhancing geometry using single x-ray line matching animal thickness and density. We conclude that the ultrafast laser-based, compact, x-ray source is a promising alternative to a microfocal x-ray tube in micro-CT systems. Its utilization might result in faster scans with lower radiation dose, and with better spatial and contrast resolution. In addition, it might allow practical implementation of dual-energy and phase-contrast imaging micro-CT that not possible with conventional micro-CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Influence of Interface Thermal Resistance on Relaxation Dynamics of Metal-Dielectric Nanocomposite Materials under Ultrafast Pulse Laser Excitation

Nanocomposite materials, including noble metal nanoparticles embedded in a dielectric host medium, are interesting because of their optical properties linked to surface plasmon resonance phenomena. For studding of nonlinear optical properties and/or energy transfer process, these materials may be excited by ultrashort pulse laser with a temporal width varying from some femtoseconds to some hund...

متن کامل

Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition

Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...

متن کامل

Graphene Quantum Dots-Coated Bismuth Nanoparticles for X-ray CT Imaging-Guided Photothermal therapy of Cancer Cells

Introduction: Theranostic nanoparticles, which integrate both diagnostic and therapeutic capabilities into one nanoagent, has great promise to ablate more effective tumoral tissue by optimizing and real-time monitoring treatment interventions, as well as monitoring therapeutic response to corresponding effect. Multifunctional theranostic nanoagent based on graphene quantum dots...

متن کامل

In vivo small animal micro-CT using nanoparticle contrast agents

Computed tomography (CT) is one of the most valuable modalities for in vivo imaging because it is fast, high-resolution, cost-effective, and non-invasive. Moreover, CT is heavily used not only in the clinic (for both diagnostics and treatment planning) but also in preclinical research as micro-CT. Although CT is inherently effective for lung and bone imaging, soft tissue imaging requires the us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006