Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach
نویسندگان
چکیده
INTRODUCTION Pulse pressure variation (PPV) has been shown to predict fluid responsiveness in ventilated intensive care unit (ICU) patients. The present study was aimed at assessing the diagnostic accuracy of PPV for prediction of fluid responsiveness by using the grey zone approach in a large population. METHODS The study pooled data of 556 patients from nine French ICUs. Hemodynamic (PPV, central venous pressure (CVP) and cardiac output) and ventilator variables were recorded. Responders were defined as patients increasing their stroke volume more than or equal to 15% after fluid challenge. The receiver operating characteristic (ROC) curve and grey zone were defined for PPV. The grey zone was evaluated according to the risk of fluid infusion in hypoxemic patients. RESULTS Fluid challenge led to increased stroke volume more than or equal to 15% in 267 patients (48%). The areas under the ROC curve of PPV and CVP were 0.73 (95% confidence interval (CI): 0.68 to 0.77) and 0.64 (95% CI 0.59 to 0.70), respectively (P<0.001). A grey zone of 4 to 17% (62% of patients) was found for PPV. A tidal volume more than or equal to 8 ml.kg(-1) and a driving pressure (plateau pressure - PEEP) more than 20 cmH2O significantly improved the area under the ROC curve for PPV. When taking into account the risk of fluid infusion, the grey zone for PPV was 2 to 13%. CONCLUSIONS In ventilated ICU patients, PPV values between 4 and 17%, encountered in 62% patients exhibiting validity prerequisites, did not predict fluid responsiveness.
منابع مشابه
Passive leg raising predicts fluid responsiveness in the critically ill.
OBJECTIVE Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. DESIGN Prospective study. SETTING Medical intensive care unit of ...
متن کاملPulse pressure variation as a predictor of fluid responsiveness in mechanically ventilated patients with spontaneous breathing activity: a pragmatic observational study
INTRODUCTION Pulse pressure variation predicts fluid responsiveness in mechanically ventilated patients passively adapted to the ventilator. Its usefulness in actively breathing ventilated patients was examined only by few studies with potential methodological shortcomings. This study sought to describe the performance of pulse pressure variation as a predictor of fluid responsiveness in hypote...
متن کاملDoes pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis
INTRODUCTION Fluid resuscitation is crucial in managing hemodynamically unstable patients. The last decade witnessed the use of pulse pressure variation (PPV) to predict fluid responsiveness. However, as far as we know, no systematic review and meta-analysis has been carried out to evaluate the value of PPV in predicting fluid responsiveness specifically upon patients admitted into intensive ca...
متن کاملPoor agreement between respiratory variations in pulse oximetry photoplethysmographic waveform amplitude and pulse pressure in intensive care unit patients.
BACKGROUND To identify fluid responsiveness, a correlation between respiratory variations in pulse pressure (DeltaPP) and respiratory variations in pulse oximetry photoplethysmographic waveform amplitude (DeltaPOP) in mechanically ventilated patients has been demonstrated. To evaluate the agreement between the two methods, knowledge about the repeatability of the methods is imperative. However,...
متن کاملRespiratory Variation in Pulse Oximetry: A Simple Fluid Responsiveness Parameter
Respiratory variation in arterial pulse pressure (ΔPP) has been shown to be the most accurate predictor of fluid responsiveness in mechanically ventilated patients, with a predictive cutoff value of 13%. However, this dynamic parameter is invasive and not widely available. The pulse oximetry plethysmographic (POP) signal resembles the arterial pressure waveform in both shape and amplitude varia...