Impact of shear stimulus, risk factor burden and early atherosclerosis on the time-course of brachial artery flow-mediated vasodilation.
نویسندگان
چکیده
OBJECTIVES Our aim was to analyze flow-mediated dilation (FMD) time-course in response to forearm occlusion in the clinical setting. METHODS AND RESULTS In 50 asymptomatic subjects, monitoring software measuring continuous beat-to-beat change in brachial artery diameter was used to determine FMD magnitude in percentage change in peak diameter from baseline (FMD-DeltaD), time to peak diameter after occlusion release (FMD-t(peak)), integrated FMD response calculated as area under dilation curve (FMD-AUC), maximum FMD rate calculated as maximal slope of dilation (FMD-MDR). FMD-DeltaD and FMD-MDR correlated positively with peak wall shear stress (P < 0.05, P < 0.01). FMD-MDR correlated negatively with age (P < 0.001), Framingham risk score (P < 0.01) and carotid intima-media thickness (P < 0.05), while FMD-DeltaD correlated negatively with Framingham risk score only (P < 0.01). After adjustment, all these correlations were independent of antihypertensive, lipid-lowering and antidiabetic therapies. All but that of FMD-MDR with intima-media thickness were also found in a subgroup of 29 untreated subjects and in a subgroup of 24 untreated and low-risk (FRS < 10%) subjects. FMD-t(peak) and FMD-AUC were not associated with shear stimulus, Framingham risk score, and intima-media thickness. CONCLUSION The kinetics of dilation (maximum rate) seem more sensitive than their magnitude in assessing FMD performance and its determinants.
منابع مشابه
Go with the flow.
Physiologists have long recognized that blood vessels vasodilate in response to an increase of flow through their lumen.1 This flow-mediated vasodilation is not due to changes in luminal pressure, but rather to the tractive force of fluid flow, or shear stress.2–4 The endothelium senses shear stress by means of a mechanotransducer apparatus that is not fully defined but that may involve cytoske...
متن کاملAssociation of Flow-mediated Dilation with Shear Rate in Patients and Healthy Volunteers
Introduction: Flow mediated-dilation (FMD) is a noninvasive test of endothelial function based on shear stressdependent nitric oxide secretion causing vasodilation. Normalization of FMD to shear stress was previously proposed. The aim of present study is an examination of relationship between shear rate and FMD in patients with hypertension and atherosclerosis in comparison with healthy volunte...
متن کاملImpaired flow-mediated vasoactivity during post-prandial phase in young healthy men.
Impaired flow-mediated vasodilation in large arteries is an expression of endothelial dysfunction and an established marker of early atherosclerosis. Post-prandial lipemia can induce an impairment of the endothelial function. The aim of our study was to evaluate the effects of post-prandial phase on flow-mediated vasodilation in a group of ten young (23 +/- 2 years) healthy men without cardiova...
متن کاملShear stress and flow-mediated dilation: all shear responses are not created equally.
SINCE THE INTRODUCTION OF brachial artery reactivity testing in 1992 by Celermajer et al. (1), the measurement of endothelial function with the use of high-frequency ultrasonography of the brachial artery has proven to be an effective research tool for the assessment of cardiovascular risk (16). To date, 12 publications have demonstrated that endothelial dysfunction as measured by impaired flow...
متن کاملLocal Shear Stress and Brachial Artery Flow–Mediated Dilation
Endothelium-dependent flow-mediated dilation is a homeostatic response to short-term increases in local shear stress. Flow-mediated dilation of the brachial artery in response to postischemic reactive hyperemia is impaired in patients with cardiovascular disease risk factors and may reflect local endothelial dysfunction in the brachial artery. However, previous studies have largely neglected th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of hypertension
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2008